Pressure data loggers

Multi-network wireless pressure logger

Model PR10

Field housing with LCD, NB-IoT, 4G Cat 1 or LoRaWAN, 8000 mAh battery or 9 to 30 V DC, vacuum up to 60 bar.

Network
NB-IoT, 4G Cat 1 or LoRaWAN
Battery
8000 mAh, or 9 to 30 V DC
Range
-1 to 0 bar up to 0 to 60 bar
Accuracy
±0.5 % or ±1 % of span

Configure PR10

Process connection
Network
Accuracy
Display unit
Order code PR10-V00-M20-NB-B-A05-BAR

No payment now. The quote comes back with the price, the lead time and the documents.

  • Built to the order code you configure
  • Datasheet and dimension drawing with the quote
  • Other ranges and connections quoted on request

PR10 is a battery powered pressure logger in a field transmitter housing with a segment LCD. One build takes NB-IoT, 4G Cat 1 or LoRaWAN, chosen in the order code, so the same instrument fits a site with cellular coverage or one served by a LoRaWAN gateway. Where power is at hand it runs from an external 9 to 30 V DC supply instead of the battery.

It is made for water and pumping: distribution network pressure zones, booster and pump stations, constant pressure supply in buildings, fire water mains and wastewater plants. Ranges run from -1 to 0 bar and 0 to 20 kPa up to 0 to 60 bar. Wetted parts are stainless steel 304, accuracy is ±0.5 % or ±1 % of span, and the housing is IP65.

Reporting is set between 1 and 1440 minutes. With a reading every minute, the 8000 mAh battery lasts 50 days at 10-minute reporting, 260 days at hourly reporting and more than 3 years at one report every 12 hours. NB-IoT reports over CoAP, 4G over MQTT, and LoRaWAN follows specification 1.0.2, Class A.

Typical points

  • Distribution network and pressure zone surveys
  • Pressure transients after pump trips
  • Hydrant and valve chamber monitoring
  • Temporary logging during commissioning

Questions about PR10

Something else? Ask us about this model

How long does the battery last?

It depends on how often the logger reports. With a reading every minute, the 8000 mAh battery lasts 50 days at 10-minute reporting, 260 days at hourly reporting and more than 3 years at one report every 12 hours. A weak signal shortens it.

Which network should I choose?

Choose by coverage at the logging point. NB-IoT and 4G Cat 1 need a cellular signal. LoRaWAN needs a gateway within 2000 m in open ground or 1000 m in urban areas. State the network in the request and it becomes a line on the quote.

Can it run from a power supply instead of the battery?

Yes. The external supply option takes 9 to 30 V DC through a cable outlet.