Submersible level transmitters

Hydrostatic probes that hang in the liquid and report its depth. For boreholes, storage tanks, reservoirs and the wet wells of sewage pump stations.

Compare submersible level transmitters

ModelNameDepth rangeOutputAccuracySupply
LT10 304 stainless submersible level transmitter 0 to 1 m up to 0 to 50 m4 to 20 mA, voltage or RS485±0.5 or ±1 % of span
LT11 316L stainless submersible level transmitter 0 to 1 m up to 0 to 50 m4 to 20 mA, voltage or RS485±0.5 or ±1 % of span
LT12 PTFE level transmitter for corrosive liquids 0 to 1 m up to 0 to 30 m4 to 20 mA, two-wire±0.5 or ±1 % of span
LT20 Low-power level probe with voltage output 0 to 1 m up to 0 to 50 mLow-voltage or ratiometric±0.5 or ±1 % of span3 to 5 V DC, 2.7 mA maximum
LT21 Low-power digital level probe, RS485 or I2C 0 to 1 m up to 0 to 50 mRS485 Modbus or I2C3 to 5 V or 2.7 to 3.6 V DC
LT22 Low-power level and temperature probe, RS485 0 to 1 m up to 0 to 50 mRS485 Modbus RTU3 to 5 V DC, 0.2 mA standby
LT40 Wireless level probe with separate terminal 0 to 1 m up to 0 to 50 m
LT41 Cellular or LoRaWAN level transmitter to 60 m 0 to 3 m up to 0 to 60 m
LT42 LoRaWAN battery level gauge with display 0 to 1 m up to 0 to 50 m

What we quote to

Every one of these changes the instrument. Send what you know; we ask about the rest.

Tell us

Depth
The deepest level to measure, from the probe to the highest liquid surface.
Medium
Clean water, groundwater, wastewater with solids, or seawater, and its temperature.
Cable
Length from the probe to the junction box, and the jacket material.
Probe body
Stainless steel, or a more resistant material for seawater and aggressive effluent.
Nose cap
Standard, or an open cap that keeps solids and grease from settling on the diaphragm.
Output
Two-wire current loop or Modbus RTU.
Accessories
Suspension clamp, junction box with vent filter, surge protection.

Choosing between options

Vented cable
The cable carries a vent tube so the probe references the atmosphere above the liquid. The cable end has to stay dry, which is why a vented junction box is usually quoted with it.
Wet wells
Sewage wet wells carry rags and grease. An open nose cap and a probe that can be lifted out for cleaning reduce maintenance visits.
Long cable runs
Outdoor boreholes and reservoirs see lightning-induced surges on long cables. Surge protection at both ends is worth quoting from the start.

Typical points

  • Borehole and well level
  • Storage tank and reservoir level
  • Wastewater wet well level for pump control
  • River, canal and channel level

Used in

Quote submersible level transmitters to your point

Send the medium, the pressure, the connection and the signal. We reply with the model, its order code and the quote.

Request a quote