Pressure transmitters

For pump discharge lines, hydraulic circuits, compressed air and building services. Each transmitter is quoted to the range, connection and signal of the point it goes on.

Pressure transmitters: models

Compare pressure transmitters

ModelNameOutputAccuracyRange
PT10 Millivolt pressure sensor, glass-fused cell 10 to 15 mV/V, four-wire±0.3 % or ±0.5 % of span0 to 6 up to 0 to 600 bar
PT11 Wide-range welded stainless transmitter 4 to 20 mA or voltage±0.5 % of span0 to 0.2 up to 0 to 600 bar
PT12 Glass-fused pressure transmitter, 0.3 % grade 4 to 20 mA or voltage±0.3 % or ±0.5 % of span0 to 6 up to 0 to 600 bar
PT13 Glass-fused transmitter, 0.5 % grade ±0.5 % or ±1 % of span0 to 6 up to 0 to 600 bar
PT14 Low-range millivolt pressure sensor 10 mV/V, four-wire±0.25 % of span0 to 0.4 up to 0 to 70 bar
PT15 Low-pressure transmitter, vacuum to 6 bar 4 to 20 mA or voltage±0.25 % or ±0.5 % of span-1 bar up to 6 bar
PT16 Precision transmitter, ±0.1 % of span 4 to 20 mA or voltage±0.1 % of span0 to 0.4 up to 0 to 600 bar
PT17 Ceramic flat-diaphragm pressure transmitter 4 to 20 mA, voltage or RS485±0.5 % or ±1 % of span0 to 2 up to 0 to 25 bar
PT18 Compact ceramic transmitter for water pumps 4 to 20 mA or 0.5 to 4.5 V±1 % of span0 to 10, 16 or 25 bar
PT21 Ultra-high pressure transmitter to 6000 bar 4 to 20 mA or voltage±0.3 or ±0.5 % of span0 to 750 up to 0 to 6000 bar
PT22 Short-body hydraulic pressure transmitter 4 to 20 mA or 0.5 to 4.5 V±0.5 or ±1 % of spanUp to 0 to 1000 bar
PT23 Mobile machinery transmitter with snubber 4 to 20 mA or voltage±0.5 or ±1 % of span0 to 6 up to 0 to 600 bar
PT24 Ceramic oil pressure transmitter to 50 bar 4 to 20 mA, two-wire±1 % of span0 to 5 up to 0 to 50 bar
PT30 Strain gauge transmitter for refrigeration 4 to 20 mA or 3 voltage outputs±0.5 % or ±1 % of span0 to 50 kPa up to 0 to 60 bar
PT31 Ceramic transmitter for refrigerant and oil 4 to 20 mA or 0.5 to 4.5 V±1 % of span0 to 10 bar up to 0 to 50 bar
PT32 Refrigerant pressure sensor with tube stub 0.5 to 4.5 V on 5 V DC±1.5 % of span0 to 20 bar or 0 to 46 bar
PT33 Compact ceramic transmitter for compressors 4 to 20 mA or 0.5 to 4.5 V±1 % of span0 to 10, 0 to 16 or 0 to 25 bar
PT34 Refrigerant pressure sensor with thermistor Ratiometric, 5 V DC supply±2 % of span1.01 to 10.25 bar absolute
PT40 Modbus pressure transmitter, RS485 or RS232 Modbus on RS485 or RS232±0.3 % or ±0.5 % of span0 to 0.2 bar up to 0 to 600 bar
PT43 Low-power RS485 pressure transmitter RS485 digital-1 to 0 bar up to 0 to 600 bar
PT44 Low-power I2C pressure sensor I2C digital±0.3 % or ±0.5 % of span0 to 0.4 bar up to 0 to 70 bar
PT50 Analog pressure and temperature transmitter Analog: 2 x 4 to 20 mA or Pt100±0.3 % or ±0.5 % of span
PT51 Pressure-temperature transmitter, probe tip Modbus RTU or 4 to 20 mA
PT52 Digital pressure and temperature transmitter RS485 or RS232 Modbus RTU±0.3 % or ±0.5 % of span
PT53 Low-power pressure and temperature sensor RS485 Modbus RTU or I2C
PT60 Clamp-mount flush diaphragm transmitter 4 to 20 mA, two-wire±0.5 % of span0 to 0.4 up to 0 to 25 bar
PT61 Threaded flush diaphragm transmitter 4 to 20 mA, two-wire±0.5 % of span0 to 0.4 up to 0 to 70 bar
PT62 Finned high-temperature pressure transmitter 4 to 20 mA or voltage±0.3 or ±0.5 % of span0 to 16 up to 0 to 1000 bar
PT70 Field housing transmitter with local display 4 to 20 mA, two-wire±0.3 % or ±0.5 % of span-1 to 0 bar up to 0 to 600 bar
PT71 Compact pressure transmitter with LED display 4 to 20 mA, two-wire±0.5 % or ±1 % of span-1 to 0 bar up to 0 to 600 bar
PT80 Barometric pressure transmitter, wall mount Analog or RS485 Modbus RTU±0.15 kPa at 25 °C30 to 120 kPa absolute

What we quote to

Every one of these changes the instrument. Send what you know; we ask about the rest.

Tell us

Pressure type
Gauge, sealed gauge or absolute.
Range
Normal working pressure and the highest pressure the line can see, including surges.
Medium
Liquid or gas, its temperature, and anything abrasive, viscous or corrosive in it.
Process connection
Thread standard (BSP, NPT or metric) and size, or a flush diaphragm for viscous media.
Output
Two-wire current loop, voltage, or Modbus RTU.
Electrical connection
DIN connector, M12 connector, or cable gland with the cable length you need.
Documents
Datasheet, calibration certificate, material certificate, as the project requires.

Choosing between options

Gauge or sealed gauge
Gauge transmitters reference the atmosphere through a vent. Sealed gauge has no vent, which suits wet or washdown locations where a vent could take in water.
Pressure spikes
Pumps with fast-closing valves and hydraulic circuits produce spikes well above the working pressure. Tell us the worst case so the quoted overpressure rating covers it.
Current or voltage
A current loop tolerates long cable runs and electrical noise. Voltage output suits short runs inside a machine or panel.

Typical points

  • Pump discharge and suction pressure
  • Hydraulic system pressure on machines
  • Compressed air headers
  • Chilled and heating water circuits

Used in

Quote pressure transmitters to your point

Send the medium, the pressure, the connection and the signal. We reply with the model, its order code and the quote.

Request a quote