PT10Millivolt pressure sensor, glass-fused cell
0 to 6 up to 0 to 600 bar · 10 to 15 mV/V, four-wire -
PT11Wide-range welded stainless transmitter
0 to 0.2 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT12Glass-fused pressure transmitter, 0.3 % grade
0 to 6 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT13Glass-fused transmitter, 0.5 % grade
0 to 6 up to 0 to 600 bar · Gauge, sealed gauge, absolute -
PT14Low-range millivolt pressure sensor
0 to 0.4 up to 0 to 70 bar · 10 mV/V, four-wire -
PT15Low-pressure transmitter, vacuum to 6 bar
-1 bar up to 6 bar · 4 to 20 mA or voltage -
PT16Precision transmitter, ±0.1 % of span
0 to 0.4 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT17Ceramic flat-diaphragm pressure transmitter
0 to 2 up to 0 to 25 bar · 4 to 20 mA, voltage or RS485 -
PT18Compact ceramic transmitter for water pumps
0 to 10, 16 or 25 bar · 4 to 20 mA or 0.5 to 4.5 V -
PT21Ultra-high pressure transmitter to 6000 bar
4 to 20 mA or voltage -
PT22Short-body hydraulic pressure transmitter
Up to 0 to 1000 bar · 4 to 20 mA or 0.5 to 4.5 V -
PT23Mobile machinery transmitter with snubber
0 to 6 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT24Ceramic oil pressure transmitter to 50 bar
4 to 20 mA, two-wire -
PT30Strain gauge transmitter for refrigeration
0 to 50 kPa up to 0 to 60 bar · 4 to 20 mA or 3 voltage outputs -
PT31Ceramic transmitter for refrigerant and oil
0 to 10 bar up to 0 to 50 bar · 4 to 20 mA or 0.5 to 4.5 V -
PT32Refrigerant pressure sensor with tube stub
0 to 20 bar or 0 to 46 bar · 0.5 to 4.5 V on 5 V DC -
PT33Compact ceramic transmitter for compressors
0 to 10, 0 to 16 or 0 to 25 bar · 4 to 20 mA or 0.5 to 4.5 V -
PT34Refrigerant pressure sensor with thermistor
1.01 to 10.25 bar absolute · Ratiometric, 5 V DC supply -
PT40Modbus pressure transmitter, RS485 or RS232
0 to 0.2 bar up to 0 to 600 bar -
PT43Low-power RS485 pressure transmitter
-1 to 0 bar up to 0 to 600 bar -
PT44Low-power I2C pressure sensor
0 to 0.4 bar up to 0 to 70 bar · I2C digital -
PT50Analog pressure and temperature transmitter
0 to 10 kPa up to 0 to 600 bar · Analog: 2 x 4 to 20 mA or Pt100 -
PT51Pressure-temperature transmitter, probe tip
0 to 6 bar up to 0 to 600 bar · Modbus RTU or 4 to 20 mA -
PT52Digital pressure and temperature transmitter
0 to 10 kPa up to 0 to 600 bar · RS485 or RS232 Modbus RTU -
PT53Low-power pressure and temperature sensor
3 to 5 V DC, 2.5 mA maximum · RS485 Modbus RTU or I2C -
PT60Clamp-mount flush diaphragm transmitter
0 to 0.4 up to 0 to 25 bar · 4 to 20 mA, two-wire -
PT61Threaded flush diaphragm transmitter
0 to 0.4 up to 0 to 70 bar · 4 to 20 mA, two-wire -
PT62Finned high-temperature pressure transmitter
0 to 16 up to 0 to 1000 bar · 4 to 20 mA or voltage -
PT70Field housing transmitter with local display
-1 to 0 bar up to 0 to 600 bar · 4 to 20 mA, two-wire -
PT71Compact pressure transmitter with LED display
-1 to 0 bar up to 0 to 600 bar · 4 to 20 mA, two-wire -
PT80Barometric pressure transmitter, wall mount
30 to 120 kPa absolute · Analog or RS485 Modbus RTU
Compare pressure transmitters
| Model | Name | Output | Accuracy | Range |
|---|---|---|---|---|
| PT10 | Millivolt pressure sensor, glass-fused cell | 10 to 15 mV/V, four-wire | ±0.3 % or ±0.5 % of span | 0 to 6 up to 0 to 600 bar |
| PT11 | Wide-range welded stainless transmitter | 4 to 20 mA or voltage | ±0.5 % of span | 0 to 0.2 up to 0 to 600 bar |
| PT12 | Glass-fused pressure transmitter, 0.3 % grade | 4 to 20 mA or voltage | ±0.3 % or ±0.5 % of span | 0 to 6 up to 0 to 600 bar |
| PT13 | Glass-fused transmitter, 0.5 % grade | ±0.5 % or ±1 % of span | 0 to 6 up to 0 to 600 bar | |
| PT14 | Low-range millivolt pressure sensor | 10 mV/V, four-wire | ±0.25 % of span | 0 to 0.4 up to 0 to 70 bar |
| PT15 | Low-pressure transmitter, vacuum to 6 bar | 4 to 20 mA or voltage | ±0.25 % or ±0.5 % of span | -1 bar up to 6 bar |
| PT16 | Precision transmitter, ±0.1 % of span | 4 to 20 mA or voltage | ±0.1 % of span | 0 to 0.4 up to 0 to 600 bar |
| PT17 | Ceramic flat-diaphragm pressure transmitter | 4 to 20 mA, voltage or RS485 | ±0.5 % or ±1 % of span | 0 to 2 up to 0 to 25 bar |
| PT18 | Compact ceramic transmitter for water pumps | 4 to 20 mA or 0.5 to 4.5 V | ±1 % of span | 0 to 10, 16 or 25 bar |
| PT21 | Ultra-high pressure transmitter to 6000 bar | 4 to 20 mA or voltage | ±0.3 or ±0.5 % of span | 0 to 750 up to 0 to 6000 bar |
| PT22 | Short-body hydraulic pressure transmitter | 4 to 20 mA or 0.5 to 4.5 V | ±0.5 or ±1 % of span | Up to 0 to 1000 bar |
| PT23 | Mobile machinery transmitter with snubber | 4 to 20 mA or voltage | ±0.5 or ±1 % of span | 0 to 6 up to 0 to 600 bar |
| PT24 | Ceramic oil pressure transmitter to 50 bar | 4 to 20 mA, two-wire | ±1 % of span | 0 to 5 up to 0 to 50 bar |
| PT30 | Strain gauge transmitter for refrigeration | 4 to 20 mA or 3 voltage outputs | ±0.5 % or ±1 % of span | 0 to 50 kPa up to 0 to 60 bar |
| PT31 | Ceramic transmitter for refrigerant and oil | 4 to 20 mA or 0.5 to 4.5 V | ±1 % of span | 0 to 10 bar up to 0 to 50 bar |
| PT32 | Refrigerant pressure sensor with tube stub | 0.5 to 4.5 V on 5 V DC | ±1.5 % of span | 0 to 20 bar or 0 to 46 bar |
| PT33 | Compact ceramic transmitter for compressors | 4 to 20 mA or 0.5 to 4.5 V | ±1 % of span | 0 to 10, 0 to 16 or 0 to 25 bar |
| PT34 | Refrigerant pressure sensor with thermistor | Ratiometric, 5 V DC supply | ±2 % of span | 1.01 to 10.25 bar absolute |
| PT40 | Modbus pressure transmitter, RS485 or RS232 | Modbus on RS485 or RS232 | ±0.3 % or ±0.5 % of span | 0 to 0.2 bar up to 0 to 600 bar |
| PT43 | Low-power RS485 pressure transmitter | RS485 digital | -1 to 0 bar up to 0 to 600 bar | |
| PT44 | Low-power I2C pressure sensor | I2C digital | ±0.3 % or ±0.5 % of span | 0 to 0.4 bar up to 0 to 70 bar |
| PT50 | Analog pressure and temperature transmitter | Analog: 2 x 4 to 20 mA or Pt100 | ±0.3 % or ±0.5 % of span | |
| PT51 | Pressure-temperature transmitter, probe tip | Modbus RTU or 4 to 20 mA | ||
| PT52 | Digital pressure and temperature transmitter | RS485 or RS232 Modbus RTU | ±0.3 % or ±0.5 % of span | |
| PT53 | Low-power pressure and temperature sensor | RS485 Modbus RTU or I2C | ||
| PT60 | Clamp-mount flush diaphragm transmitter | 4 to 20 mA, two-wire | ±0.5 % of span | 0 to 0.4 up to 0 to 25 bar |
| PT61 | Threaded flush diaphragm transmitter | 4 to 20 mA, two-wire | ±0.5 % of span | 0 to 0.4 up to 0 to 70 bar |
| PT62 | Finned high-temperature pressure transmitter | 4 to 20 mA or voltage | ±0.3 or ±0.5 % of span | 0 to 16 up to 0 to 1000 bar |
| PT70 | Field housing transmitter with local display | 4 to 20 mA, two-wire | ±0.3 % or ±0.5 % of span | -1 to 0 bar up to 0 to 600 bar |
| PT71 | Compact pressure transmitter with LED display | 4 to 20 mA, two-wire | ±0.5 % or ±1 % of span | -1 to 0 bar up to 0 to 600 bar |
| PT80 | Barometric pressure transmitter, wall mount | Analog or RS485 Modbus RTU | ±0.15 kPa at 25 °C | 30 to 120 kPa absolute |
What we quote to
Every one of these changes the instrument. Send what you know; we ask about the rest.
Tell us
- Pressure type
- Gauge, sealed gauge or absolute.
- Range
- Normal working pressure and the highest pressure the line can see, including surges.
- Medium
- Liquid or gas, its temperature, and anything abrasive, viscous or corrosive in it.
- Process connection
- Thread standard (BSP, NPT or metric) and size, or a flush diaphragm for viscous media.
- Output
- Two-wire current loop, voltage, or Modbus RTU.
- Electrical connection
- DIN connector, M12 connector, or cable gland with the cable length you need.
- Documents
- Datasheet, calibration certificate, material certificate, as the project requires.
Choosing between options
- Gauge or sealed gauge
- Gauge transmitters reference the atmosphere through a vent. Sealed gauge has no vent, which suits wet or washdown locations where a vent could take in water.
- Pressure spikes
- Pumps with fast-closing valves and hydraulic circuits produce spikes well above the working pressure. Tell us the worst case so the quoted overpressure rating covers it.
- Current or voltage
- A current loop tolerates long cable runs and electrical noise. Voltage output suits short runs inside a machine or panel.
Typical points
- Pump discharge and suction pressure
- Hydraulic system pressure on machines
- Compressed air headers
- Chilled and heating water circuits
Used in