Low-pressure transmitter, vacuum to 6 bar
Laser-welded 304 stainless, from -1 bar up to 6 bar at ±0.25 % of span, for water, HVAC and suction lines.
- Range
- -1 bar up to 6 bar
- Accuracy
- ±0.25 % or ±0.5 % of span
- Output
- 4 to 20 mA or voltage
- Protection
- IP65
- Built to the order code you configure
- Datasheet and dimension drawing with the quote
- Other ranges and connections quoted on request
PT15 is built for the low end of the scale: vacuum and ranges up to 6 bar, gauge or absolute. The pressure chamber is 304 stainless steel, laser welded, and the electronics are temperature compensated from -20 to 85 °C. Accuracy is ±0.25 % or ±0.5 % of span, with ±0.1 % of span per year stability.
It goes on building water and booster sets, chilled and heating water circuits, compressed air lines and pump suction, where pressures stay within a few bar. A range can start in vacuum, for example -1 to 1 bar on a suction line that sees both. It also suits test benches for low-pressure components.
Overpressure is 1.5 x range and burst pressure 2 x range. Outputs are 4 to 20 mA two-wire, or 0 to 5 V, 0 to 10 V or 0.5 to 4.5 V three-wire, with surge and reverse polarity protection. The 22 mm body takes DIN 43650 form A or form C, M12, Packard, AMP, Deutsch DT04 or circular connectors, or a cable outlet, IP65.
Typical points
- Pump discharge and suction pressure
- Hydraulic system pressure on machines
- Compressed air headers
- Chilled and heating water circuits
Measurement
| Pressure type | Gauge, absolute |
|---|---|
| Ranges | Within -1 to 6 bar |
| Accuracy | ±0.25 % or ±0.5 % of span |
| Long-term stability | ±0.1 % of span per year |
| Overpressure | 1.5 x range |
| Burst pressure | 2 x range |
| Zero temperature drift | ±0.02 % of span per °C |
| Span temperature drift | ±0.02 % of span per °C |
| Compensated temperature | -20 to 85 °C |
Medium and environment
| Medium temperature | -40 to 85 °C |
|---|---|
| Storage temperature | -40 to 125 °C |
| Shock | 100 g (11 ms) |
| Material | 304 stainless steel, laser welded |
Electrical
| Output | 4 to 20 mA two-wire; 0 to 5 V, 0 to 10 V or 0.5 to 4.5 V three-wire |
|---|---|
| Supply | 9 to 30 V DC (4 to 20 mA, 0 to 5 V); 15 to 30 V DC (0 to 10 V); 5 V DC (0.5 to 4.5 V) |
| Protection circuits | Surge and reverse polarity protection |
| Electrical connection | DIN 43650 form A or form C, M12, Packard, circular connector, AMP, Deutsch DT04-3P or DT04-4P, cable outlet or watertight cable outlet |
| Protection | IP65 |
Mechanical
| Process connection | G1/8, G1/4, G3/8, G1/2, 1/8 NPT, 1/4 NPT, 3/8 NPT, 1/2 NPT, R1/8, R1/4, R3/8, R1/2, M12 x 1.5, M18 x 1.5, M20 x 1.5, M14 x 1.5, 7/16-20 UNF |
|---|---|
| Body diameter | 22 mm |
| Wrench size | 22 mm |
Common configurations. Any combination from the ordering code can be quoted.
| Range | Pressure type | Process connection | Output | Electrical connection | Accuracy | Order code |
|---|---|---|---|---|---|---|
| -1 to 0 bar | Gauge | G1/4 male | 0.5 to 4.5 V | Packard | ±0.5 % | PT15-V00-G-B2-H-P-A05 |
| -1 to 1 bar | Gauge | G1/4 male | 4 to 20 mA | DIN 43650 form A | ±0.5 % | PT15-V01-G-B2-I-D-A05 |
| 0 to 1 bar | Gauge | G1/2 male | 4 to 20 mA | DIN 43650 form A | ±0.25 % | PT15-001-G-B4-I-D-A025 |
| 0 to 2 bar | Absolute | G1/4 male | 4 to 20 mA | M12 | ±0.25 % | PT15-002-A-B2-I-M-A025 |
| 0 to 4 bar | Gauge | G1/4 male | 0 to 10 V | M12 | ±0.25 % | PT15-004-G-B2-V10-M-A025 |
| 0 to 6 bar | Gauge | 1/4 NPT male | 4 to 20 mA | Packard | ±0.5 % | PT15-006-G-N2-I-P-A05 |
One code from each group, in this order. Example: PT15-V00-G-B1-I-D-A025.
Range
| V00 | -1 to 0 bar |
|---|---|
| V01 | -1 to 1 bar |
| 001 | 0 to 1 bar |
| 002 | 0 to 2 bar |
| 004 | 0 to 4 bar |
| 006 | 0 to 6 bar |
| X | Other range, state in the request |
Pressure type
| G | Gauge |
|---|---|
| A | Absolute |
Process connection
| B1 | G1/8 male |
|---|---|
| B2 | G1/4 male |
| B3 | G3/8 male |
| B4 | G1/2 male |
| N2 | 1/4 NPT male |
| N4 | 1/2 NPT male |
| R2 | R1/4 male |
| R4 | R1/2 male |
| M12 | M12 x 1.5 male |
| M18 | M18 x 1.5 male |
| M20 | M20 x 1.5 male |
| U7 | 7/16-20 UNF male |
Output
| I | 4 to 20 mA, two-wire |
|---|---|
| V5 | 0 to 5 V, three-wire |
| V10 | 0 to 10 V, three-wire |
| H | 0.5 to 4.5 V, three-wire, 5 V DC supply |
Electrical connection
| D | DIN 43650 form A connector |
|---|---|
| DC | DIN 43650 form C connector |
| P | Packard connector |
| M | M12 connector, four-pin |
| A | Circular connector |
| C | Cable outlet |
| CW | Watertight cable outlet |
| AM | AMP connector, two-pin |
| T3 | Deutsch DT04-3P connector |
| T4 | Deutsch DT04-4P connector |
Accuracy
| A025 | ±0.25 % of span |
|---|---|
| A05 | ±0.5 % of span |
- DatasheetPDF
- Dimension drawingSent with the quote
- Calibration certificate, per unit on requestSent with the quote
Questions about PT15
Something else? Ask us about this model
Can PT15 measure vacuum?
Yes. Ranges can start at -1 bar, for example -1 to 0 bar or -1 to 1 bar on a pump suction. Any other range within -1 to 6 bar can be stated in the request.
What if the pressure goes above 6 bar?
PT11 uses the same welded 304 stainless steel construction up to 600 bar. For hydraulic circuits with large spikes, PT12 takes 3 x range.
Other pressure transmitters
See all 31-
PT10Millivolt pressure sensor, glass-fused cell
0 to 6 up to 0 to 600 bar · 10 to 15 mV/V, four-wire -
PT11Wide-range welded stainless transmitter
0 to 0.2 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT12Glass-fused pressure transmitter, 0.3 % grade
0 to 6 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT13Glass-fused transmitter, 0.5 % grade
0 to 6 up to 0 to 600 bar · Gauge, sealed gauge, absolute -
PT14Low-range millivolt pressure sensor
0 to 0.4 up to 0 to 70 bar · 10 mV/V, four-wire -
PT16Precision transmitter, ±0.1 % of span
0 to 0.4 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT17Ceramic flat-diaphragm pressure transmitter
0 to 2 up to 0 to 25 bar · 4 to 20 mA, voltage or RS485 -
PT18Compact ceramic transmitter for water pumps
0 to 10, 16 or 25 bar · 4 to 20 mA or 0.5 to 4.5 V