Ceramic flat-diaphragm pressure transmitter
Ceramic sensing element, 2 to 25 bar gauge, with 4 to 20 mA, voltage or RS485 output for water and air.
- Range
- 0 to 2 up to 0 to 25 bar
- Accuracy
- ±0.5 % or ±1 % of span
- Output
- 4 to 20 mA, voltage or RS485
- Sensing element
- Ceramic, flat diaphragm
- Built to the order code you configure
- Datasheet and dimension drawing with the quote
- Other ranges and connections quoted on request
PT17 uses a flat ceramic diaphragm with a piezoresistive bridge, held in a stainless steel housing, with zero and full scale set by laser trimming. The ceramic diaphragm resists corrosion and wear. Standard ranges are 0 to 2, 6, 10, 16 and 25 bar gauge, at ±0.5 % or ±1 % of span.
It fits water treatment, air compressors, refrigeration and HVAC circuits, and hydraulic and pneumatic equipment up to 25 bar. Besides 4 to 20 mA and 0 to 5 V, 0 to 10 V or 0.5 to 4.5 V, it is available with a four-wire RS485 digital output for a direct link to a controller or gateway.
Overpressure is 1.5 x range and burst pressure 2 x range. It is rated for ±20 g vibration and 100 g shock, and operates from -40 to 85 °C. The 22 mm body takes a cable outlet, M12, Packard, or DIN 43650 form A or form C connectors, on G1/4, G1/2, 1/4 NPT, M12 x 1.5 or M20 x 1.5 threads.
Typical points
- Pump discharge and suction pressure
- Hydraulic system pressure on machines
- Compressed air headers
- Chilled and heating water circuits
Measurement
| Pressure type | Gauge |
|---|---|
| Ranges | 0 to 2, 0 to 6, 0 to 10, 0 to 16, 0 to 25 bar |
| Accuracy | ±0.5 % or ±1 % of span |
| Overpressure | 1.5 x range |
| Burst pressure | 2 x range |
| Sensing element | Ceramic flat diaphragm, piezoresistive |
Medium and environment
| Operating temperature | -40 to 85 °C |
|---|---|
| Storage temperature | -40 to 105 °C |
| Vibration | ±20 g |
| Shock | 100 g (11 ms) |
| Housing | Stainless steel |
Electrical
| Output | 4 to 20 mA two-wire; 0 to 5 V, 0 to 10 V or 0.5 to 4.5 V three-wire; RS485 four-wire |
|---|---|
| Supply | 9 to 30 V DC (4 to 20 mA, 0 to 5 V); 15 to 30 V DC (0 to 10 V); 5 V DC or 9 to 30 V DC (0.5 to 4.5 V); 3.3 to 30 V DC (RS485) |
| Electrical connection | Cable outlet, M12, Packard, DIN 43650 form A or form C |
| Protection | IP65 |
Mechanical
| Process connection | G1/4, G1/2, 1/4 NPT, M12 x 1.5, M20 x 1.5 |
|---|---|
| Body diameter | 22 mm |
| Wrench size | 22 mm |
Common configurations. Any combination from the ordering code can be quoted.
| Range | Process connection | Output | Electrical connection | Accuracy | Order code |
|---|---|---|---|---|---|
| 0 to 2 bar | 1/4 NPT male | 0.5 to 4.5 V | Packard | ±1 % | PT17-002-N2-H-P-A1 |
| 0 to 6 bar | G1/4 male | 4 to 20 mA | DIN 43650 form A | ±0.5 % | PT17-006-B2-I-D-A05 |
| 0 to 10 bar | G1/4 male | 4 to 20 mA | DIN 43650 form A | ±0.5 % | PT17-010-B2-I-D-A05 |
| 0 to 10 bar | G1/4 male | 0 to 5 V | DIN 43650 form C | ±1 % | PT17-010-B2-V5-DC-A1 |
| 0 to 16 bar | G1/2 male | RS485 | Cable outlet | ±0.5 % | PT17-016-B4-M-C-A05 |
| 0 to 25 bar | M20 x 1.5 male | 0 to 10 V | M12 | ±0.5 % | PT17-025-M20-V10-M-A05 |
One code from each group, in this order. Example: PT17-002-B2-I-D-A05.
Range
| 002 | 0 to 2 bar |
|---|---|
| 006 | 0 to 6 bar |
| 010 | 0 to 10 bar |
| 016 | 0 to 16 bar |
| 025 | 0 to 25 bar |
| X | Other range, state in the request |
Process connection
| B2 | G1/4 male |
|---|---|
| B4 | G1/2 male |
| N2 | 1/4 NPT male |
| M12 | M12 x 1.5 male |
| M20 | M20 x 1.5 male |
Output
| I | 4 to 20 mA, two-wire |
|---|---|
| V5 | 0 to 5 V, three-wire |
| V10 | 0 to 10 V, three-wire |
| H | 0.5 to 4.5 V, three-wire, 5 V DC supply |
| H9 | 0.5 to 4.5 V, three-wire, 9 to 30 V DC supply |
| M | RS485, four-wire |
Electrical connection
| D | DIN 43650 form A connector |
|---|---|
| DC | DIN 43650 form C connector |
| P | Packard connector |
| M | M12 connector, four-pin |
| C | Cable outlet |
Accuracy
| A05 | ±0.5 % of span |
|---|---|
| A1 | ±1 % of span |
- DatasheetPDF
- Dimension drawingSent with the quote
- Calibration certificate, per unit on requestSent with the quote
Questions about PT17
Something else? Ask us about this model
Why choose a ceramic diaphragm?
Ceramic resists corrosion and wear. PT17 suits water treatment, compressed air and refrigeration points up to 25 bar. For higher ranges or hydraulic spikes, PT12 goes to 600 bar with 3 x range overpressure.
Is there a digital output?
Yes, RS485 on four wires with a 3.3 to 30 V DC supply. State the protocol and settings your controller expects in the request, and the quote confirms them.
Are ranges above 25 bar available?
The standard ranges stop at 25 bar. State another range in the request and the quote confirms whether it can be supplied.
Other pressure transmitters
See all 31-
PT10Millivolt pressure sensor, glass-fused cell
0 to 6 up to 0 to 600 bar · 10 to 15 mV/V, four-wire -
PT11Wide-range welded stainless transmitter
0 to 0.2 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT12Glass-fused pressure transmitter, 0.3 % grade
0 to 6 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT13Glass-fused transmitter, 0.5 % grade
0 to 6 up to 0 to 600 bar · Gauge, sealed gauge, absolute -
PT14Low-range millivolt pressure sensor
0 to 0.4 up to 0 to 70 bar · 10 mV/V, four-wire -
PT15Low-pressure transmitter, vacuum to 6 bar
-1 bar up to 6 bar · 4 to 20 mA or voltage -
PT16Precision transmitter, ±0.1 % of span
0 to 0.4 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT18Compact ceramic transmitter for water pumps
0 to 10, 16 or 25 bar · 4 to 20 mA or 0.5 to 4.5 V