Pressure transmitters

Ceramic flat-diaphragm pressure transmitter

Model PT17

Ceramic sensing element, 2 to 25 bar gauge, with 4 to 20 mA, voltage or RS485 output for water and air.

Range
0 to 2 up to 0 to 25 bar
Accuracy
±0.5 % or ±1 % of span
Output
4 to 20 mA, voltage or RS485
Sensing element
Ceramic, flat diaphragm

Configure PT17

Accuracy
Order code PT17-002-B2-I-D-A05

No payment now. The quote comes back with the price, the lead time and the documents.

  • Built to the order code you configure
  • Datasheet and dimension drawing with the quote
  • Other ranges and connections quoted on request

PT17 uses a flat ceramic diaphragm with a piezoresistive bridge, held in a stainless steel housing, with zero and full scale set by laser trimming. The ceramic diaphragm resists corrosion and wear. Standard ranges are 0 to 2, 6, 10, 16 and 25 bar gauge, at ±0.5 % or ±1 % of span.

It fits water treatment, air compressors, refrigeration and HVAC circuits, and hydraulic and pneumatic equipment up to 25 bar. Besides 4 to 20 mA and 0 to 5 V, 0 to 10 V or 0.5 to 4.5 V, it is available with a four-wire RS485 digital output for a direct link to a controller or gateway.

Overpressure is 1.5 x range and burst pressure 2 x range. It is rated for ±20 g vibration and 100 g shock, and operates from -40 to 85 °C. The 22 mm body takes a cable outlet, M12, Packard, or DIN 43650 form A or form C connectors, on G1/4, G1/2, 1/4 NPT, M12 x 1.5 or M20 x 1.5 threads.

Typical points

  • Pump discharge and suction pressure
  • Hydraulic system pressure on machines
  • Compressed air headers
  • Chilled and heating water circuits

Questions about PT17

Something else? Ask us about this model

Why choose a ceramic diaphragm?

Ceramic resists corrosion and wear. PT17 suits water treatment, compressed air and refrigeration points up to 25 bar. For higher ranges or hydraulic spikes, PT12 goes to 600 bar with 3 x range overpressure.

Is there a digital output?

Yes, RS485 on four wires with a 3.3 to 30 V DC supply. State the protocol and settings your controller expects in the request, and the quote confirms them.

Are ranges above 25 bar available?

The standard ranges stop at 25 bar. State another range in the request and the quote confirms whether it can be supplied.