Glass-fused transmitter, 0.5 % grade
Same one-piece 17-4PH cell as PT12 at ±0.5 % or ±1 % of span, in gauge, sealed gauge or absolute reference.
- Range
- 0 to 6 up to 0 to 600 bar
- Accuracy
- ±0.5 % or ±1 % of span
- Pressure type
- Gauge, sealed gauge, absolute
- Overpressure
- 3 x range, burst 5 x range
- Built to the order code you configure
- Datasheet and dimension drawing with the quote
- Other ranges and connections quoted on request
PT13 shares the glass-fused 17-4PH construction of PT12: a one-piece pressure chamber with no weld and no O-ring in contact with the medium, 3 x range overpressure and 5 x range burst pressure. It is the general-duty grade, at ±0.5 % or ±1 % of span with ±0.2 % of span per year stability, compensated from -10 to 70 °C.
Ranges run from 0 to 6 bar up to 0 to 600 bar, with gauge, sealed gauge or absolute reference. Sealed gauge has no vent, which suits pump pits, washdown areas and outdoor booster sets where a vent could take in water. Absolute suits gas lines and test benches that must not follow changes in barometric pressure.
Outputs are 4 to 20 mA two-wire, or 0 to 5 V, 0 to 10 V or 0.5 to 4.5 V three-wire, with surge and reverse polarity protection. Besides male threads from G1/4 to M20 x 1.5, it is available with female G1/4 and female 7/16-20 UNF ports. Connector choices match PT12, from DIN 43650 to Deutsch DT04.
Typical points
- Pump discharge and suction pressure
- Hydraulic system pressure on machines
- Compressed air headers
- Chilled and heating water circuits
Measurement
| Pressure type | Gauge, sealed gauge, absolute |
|---|---|
| Ranges | 0 to 6 bar up to 0 to 600 bar |
| Accuracy | ±0.5 % or ±1 % of span |
| Long-term stability | ±0.2 % of span per year |
| Overpressure | 3 x range |
| Burst pressure | 5 x range |
| Zero temperature drift | ±0.02 % of span per °C |
| Span temperature drift | ±0.02 % of span per °C |
| Compensated temperature | -10 to 70 °C |
Medium and environment
| Medium temperature | -40 to 85 °C |
|---|---|
| Storage temperature | -40 to 125 °C |
| Shock | 100 g (11 ms) |
| Wetted parts | 17-4PH stainless steel |
| Housing | 304 stainless steel |
Electrical
| Output | 4 to 20 mA two-wire; 0 to 5 V, 0 to 10 V or 0.5 to 4.5 V three-wire |
|---|---|
| Supply | 9 to 30 V DC (4 to 20 mA, 0 to 5 V); 15 to 30 V DC (0 to 10 V); 5 V DC (0.5 to 4.5 V) |
| Protection circuits | Surge and reverse polarity protection |
| Electrical connection | DIN 43650 form A or form C, M12, Packard, circular connector, AMP, Deutsch DT04-3P or DT04-4P, cable outlet or watertight cable outlet |
| Protection | IP65 |
Mechanical
| Process connection | Male G1/4, G3/8, G1/2, 1/4 NPT, 1/2 NPT, R1/4, R1/2, M14 x 1.5, M18 x 1.5, M20 x 1.5, 7/16-20 UNF; female G1/4, 1/4 NPT, 7/16-20 UNF |
|---|---|
| Construction | One-piece 17-4PH pressure chamber, glass-fused sensing element, no weld, no O-ring |
| Body diameter | 22 mm |
| Wrench size | 22 mm |
Common configurations. Any combination from the ordering code can be quoted.
| Range | Pressure type | Process connection | Output | Electrical connection | Accuracy | Order code |
|---|---|---|---|---|---|---|
| 0 to 6 bar | Absolute | G1/4 male | 0 to 10 V | M12 | ±0.5 % | PT13-006-A-B2-V10-M-A05 |
| 0 to 10 bar | Gauge | G1/4 male | 4 to 20 mA | DIN 43650 form A | ±0.5 % | PT13-010-G-B2-I-D-A05 |
| 0 to 16 bar | Sealed gauge | G1/2 male | 4 to 20 mA | Watertight cable outlet | ±0.5 % | PT13-016-S-B4-I-CW-A05 |
| 0 to 60 bar | Gauge | G1/4 female | 0 to 5 V | Deutsch DT04-4P | ±1 % | PT13-060-G-FB2-V5-T4-A1 |
| 0 to 250 bar | Sealed gauge | 7/16-20 UNF female | 0.5 to 4.5 V | Packard | ±1 % | PT13-250-S-FU7-H-P-A1 |
| 0 to 400 bar | Sealed gauge | M20 x 1.5 male | 4 to 20 mA | DIN 43650 form A | ±0.5 % | PT13-400-S-M20-I-D-A05 |
One code from each group, in this order. Example: PT13-006-G-B2-I-D-A05.
Range
| 006 | 0 to 6 bar |
|---|---|
| 010 | 0 to 10 bar |
| 016 | 0 to 16 bar |
| 025 | 0 to 25 bar |
| 040 | 0 to 40 bar |
| 060 | 0 to 60 bar |
| 100 | 0 to 100 bar |
| 160 | 0 to 160 bar |
| 250 | 0 to 250 bar |
| 400 | 0 to 400 bar |
| 600 | 0 to 600 bar |
| X | Other range, state in the request |
Pressure type
| G | Gauge |
|---|---|
| S | Sealed gauge |
| A | Absolute |
Process connection
| B2 | G1/4 male |
|---|---|
| B4 | G1/2 male |
| N2 | 1/4 NPT male |
| N4 | 1/2 NPT male |
| R2 | R1/4 male |
| R4 | R1/2 male |
| M14 | M14 x 1.5 male |
| M18 | M18 x 1.5 male |
| M20 | M20 x 1.5 male |
| U7 | 7/16-20 UNF male |
| FB2 | G1/4 female |
| FU7 | 7/16-20 UNF female |
Output
| I | 4 to 20 mA, two-wire |
|---|---|
| V5 | 0 to 5 V, three-wire |
| V10 | 0 to 10 V, three-wire |
| H | 0.5 to 4.5 V, three-wire, 5 V DC supply |
Electrical connection
| D | DIN 43650 form A connector |
|---|---|
| DC | DIN 43650 form C connector |
| P | Packard connector |
| M | M12 connector, four-pin |
| A | Circular connector |
| C | Cable outlet |
| CW | Watertight cable outlet |
| AM | AMP connector, two-pin |
| T3 | Deutsch DT04-3P connector |
| T4 | Deutsch DT04-4P connector |
Accuracy
| A05 | ±0.5 % of span |
|---|---|
| A1 | ±1 % of span |
- DatasheetPDF
- Dimension drawingSent with the quote
- Calibration certificate, per unit on requestSent with the quote
Questions about PT13
Something else? Ask us about this model
What is the difference between PT12 and PT13?
Both use the one-piece glass-fused 17-4PH cell. PT12 is gauge only, at ±0.3 % or ±0.5 % of span with ±0.1 % of span per year stability. PT13 is ±0.5 % or ±1 % with ±0.2 % per year, and adds sealed gauge, absolute and female ports.
When is sealed gauge the better choice?
Gauge references the atmosphere through a vent. Sealed gauge has no vent, which suits washdown areas, pits and outdoor equipment where a vent could take in water.
Other pressure transmitters
See all 31-
PT10Millivolt pressure sensor, glass-fused cell
0 to 6 up to 0 to 600 bar · 10 to 15 mV/V, four-wire -
PT11Wide-range welded stainless transmitter
0 to 0.2 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT12Glass-fused pressure transmitter, 0.3 % grade
0 to 6 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT14Low-range millivolt pressure sensor
0 to 0.4 up to 0 to 70 bar · 10 mV/V, four-wire -
PT15Low-pressure transmitter, vacuum to 6 bar
-1 bar up to 6 bar · 4 to 20 mA or voltage -
PT16Precision transmitter, ±0.1 % of span
0 to 0.4 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT17Ceramic flat-diaphragm pressure transmitter
0 to 2 up to 0 to 25 bar · 4 to 20 mA, voltage or RS485 -
PT18Compact ceramic transmitter for water pumps
0 to 10, 16 or 25 bar · 4 to 20 mA or 0.5 to 4.5 V