Pressure transmitters

Millivolt pressure sensor, glass-fused cell

Model PT10

Unamplified 10 to 15 mV/V output from a one-piece 17-4PH cell, 6 to 600 bar, for your own amplifier.

Range
0 to 6 up to 0 to 600 bar
Accuracy
±0.3 % or ±0.5 % of span
Output
10 to 15 mV/V, four-wire
Overpressure
3 x range, burst 5 x range

Configure PT10

Pressure type
Process connection
Accuracy
Order code PT10-006-G-M20-C-A03

No payment now. The quote comes back with the price, the lead time and the documents.

  • Built to the order code you configure
  • Datasheet and dimension drawing with the quote
  • Other ranges and connections quoted on request

PT10 is a bare pressure sensor with no amplifier inside. MEMS silicon strain gauges are glass-fused onto a 17-4PH stainless steel cell, and the bridge gives 10 to 15 mV/V on four wires from a 3 to 10 V DC excitation, 5 V DC recommended. Ranges run from 0 to 6 bar up to 0 to 600 bar, gauge or sealed gauge, at ±0.3 % or ±0.5 % of span.

It is meant for machine builders and test bench designers who already have a strain gauge amplifier, a bridge input card or their own conditioning board, and want the sensing element without a second set of electronics. Hydraulic test stands, presses, injection moulding machines and pump test rigs are the usual points.

The pressure chamber is machined from one piece of 17-4PH with no weld and no O-ring in contact with the medium. Overpressure is 3 x range and burst pressure 5 x range, with ±0.1 % of span per year stability. Process connection is M20 x 1.5, G1/4 or 1/4 NPT. Electrical connection is a cable outlet, an M12 connector or a circular connector, all IP65.

Typical points

  • Pump discharge and suction pressure
  • Hydraulic system pressure on machines
  • Compressed air headers
  • Chilled and heating water circuits

Questions about PT10

Something else? Ask us about this model

What does PT10 need on the electrical side?

A regulated excitation of 3 to 10 V DC, 5 V DC recommended, and an input that reads a millivolt bridge signal, such as a strain gauge amplifier. PT10 has no amplifier of its own. For a 4 to 20 mA or voltage signal from the same glass-fused construction, see PT12.

Gauge or sealed gauge?

Gauge references the atmosphere through a vent. Sealed gauge has no vent, which suits wet locations and the higher ranges, where changes in atmospheric pressure are a negligible part of the span.

Can I order a thread or connector that is not listed?

Yes. State the thread or connector in the request and it becomes a line on the quote.