Glass-fused pressure transmitter, 0.3 % grade
One-piece 17-4PH cell, no weld or O-ring, 6 to 600 bar gauge with 3 x range overpressure for hydraulics.
- Range
- 0 to 6 up to 0 to 600 bar
- Accuracy
- ±0.3 % or ±0.5 % of span
- Output
- 4 to 20 mA or voltage
- Overpressure
- 3 x range, burst 5 x range
- Built to the order code you configure
- Datasheet and dimension drawing with the quote
- Other ranges and connections quoted on request
PT12 uses silicon strain gauges glass-fused onto a 17-4PH stainless steel pressure chamber, machined from one piece with no weld and no O-ring in contact with the medium. Ranges run from 0 to 6 bar up to 0 to 600 bar gauge, at ±0.3 % or ±0.5 % of span, with ±0.1 % of span per year stability and compensation from -20 to 85 °C.
The one-piece cell takes 3 x range without damage and has a burst pressure of 5 x range. That margin suits hydraulic power units, presses, mobile machinery and high-pressure pumps, where spikes from valves and cylinders reach well above the working pressure. With no internal seal in contact with the medium, the same unit serves oil, water and air.
Outputs are 4 to 20 mA two-wire, or 0 to 5 V, 0 to 10 V or 0.5 to 4.5 V three-wire, with surge and reverse polarity protection. The 22 mm body takes DIN 43650 form A or form C, M12, Packard, AMP, Deutsch DT04 or circular connectors, or a cable outlet, on threads from G1/8 to 7/16-20 UNF.
Typical points
- Pump discharge and suction pressure
- Hydraulic system pressure on machines
- Compressed air headers
- Chilled and heating water circuits
Measurement
| Pressure type | Gauge |
|---|---|
| Ranges | 0 to 6 bar up to 0 to 600 bar |
| Accuracy | ±0.3 % or ±0.5 % of span |
| Long-term stability | ±0.1 % of span per year |
| Overpressure | 3 x range |
| Burst pressure | 5 x range |
| Zero temperature drift | ±0.02 % of span per °C |
| Span temperature drift | ±0.02 % of span per °C |
| Compensated temperature | -20 to 85 °C |
Medium and environment
| Medium temperature | -40 to 85 °C |
|---|---|
| Storage temperature | -40 to 125 °C |
| Shock | 100 g (11 ms) |
| Wetted parts | 17-4PH stainless steel |
| Housing | 304 stainless steel |
Electrical
| Output | 4 to 20 mA two-wire; 0 to 5 V, 0 to 10 V or 0.5 to 4.5 V three-wire |
|---|---|
| Supply | 9 to 30 V DC (4 to 20 mA, 0 to 5 V); 15 to 30 V DC (0 to 10 V); 5 V DC (0.5 to 4.5 V) |
| Protection circuits | Surge and reverse polarity protection |
| Electrical connection | DIN 43650 form A or form C, M12, Packard, circular connector, AMP, Deutsch DT04-3P or DT04-4P, cable outlet or watertight cable outlet |
| Protection | IP65 |
Mechanical
| Process connection | G1/8, G1/4, G3/8, G1/2, 1/8 NPT, 1/4 NPT, 3/8 NPT, 1/2 NPT, R1/8, R1/4, R3/8, R1/2, M12 x 1.5, M14 x 1.5, M18 x 1.5, M20 x 1.5, 7/16-20 UNF |
|---|---|
| Construction | One-piece 17-4PH pressure chamber, glass-fused sensing element, no weld, no O-ring |
| Body diameter | 22 mm |
| Wrench size | 22 mm |
Common configurations. Any combination from the ordering code can be quoted.
| Range | Process connection | Output | Electrical connection | Accuracy | Order code |
|---|---|---|---|---|---|
| 0 to 16 bar | G1/4 male | 4 to 20 mA | DIN 43650 form A | ±0.5 % | PT12-016-B2-I-D-A05 |
| 0 to 40 bar | G1/4 male | 4 to 20 mA | M12 | ±0.3 % | PT12-040-B2-I-M-A03 |
| 0 to 100 bar | M20 x 1.5 male | 4 to 20 mA | DIN 43650 form A | ±0.3 % | PT12-100-M20-I-D-A03 |
| 0 to 250 bar | 7/16-20 UNF male | 0.5 to 4.5 V | Deutsch DT04-3P | ±0.5 % | PT12-250-U7-H-T3-A05 |
| 0 to 400 bar | 1/4 NPT male | 4 to 20 mA | Packard | ±0.5 % | PT12-400-N2-I-P-A05 |
| 0 to 600 bar | G1/4 male | 0 to 10 V | M12 | ±0.3 % | PT12-600-B2-V10-M-A03 |
One code from each group, in this order. Example: PT12-006-B1-I-D-A03.
Range
| 006 | 0 to 6 bar |
|---|---|
| 010 | 0 to 10 bar |
| 016 | 0 to 16 bar |
| 025 | 0 to 25 bar |
| 040 | 0 to 40 bar |
| 060 | 0 to 60 bar |
| 100 | 0 to 100 bar |
| 160 | 0 to 160 bar |
| 250 | 0 to 250 bar |
| 400 | 0 to 400 bar |
| 600 | 0 to 600 bar |
| X | Other range, state in the request |
Process connection
| B1 | G1/8 male |
|---|---|
| B2 | G1/4 male |
| B3 | G3/8 male |
| B4 | G1/2 male |
| N2 | 1/4 NPT male |
| N4 | 1/2 NPT male |
| R2 | R1/4 male |
| R4 | R1/2 male |
| M12 | M12 x 1.5 male |
| M18 | M18 x 1.5 male |
| M20 | M20 x 1.5 male |
| U7 | 7/16-20 UNF male |
Output
| I | 4 to 20 mA, two-wire |
|---|---|
| V5 | 0 to 5 V, three-wire |
| V10 | 0 to 10 V, three-wire |
| H | 0.5 to 4.5 V, three-wire, 5 V DC supply |
Electrical connection
| D | DIN 43650 form A connector |
|---|---|
| DC | DIN 43650 form C connector |
| P | Packard connector |
| M | M12 connector, four-pin |
| A | Circular connector |
| C | Cable outlet |
| CW | Watertight cable outlet |
| AM | AMP connector, two-pin |
| T3 | Deutsch DT04-3P connector |
| T4 | Deutsch DT04-4P connector |
Accuracy
| A03 | ±0.3 % of span |
|---|---|
| A05 | ±0.5 % of span |
- DatasheetPDF
- Dimension drawingSent with the quote
- Calibration certificate, per unit on requestSent with the quote
Questions about PT12
Something else? Ask us about this model
What does the glass-fused cell change?
The pressure chamber is one piece of 17-4PH stainless steel, with no weld and no O-ring in contact with the medium. That gives 3 x range overpressure and 5 x range burst pressure, against 1.5 x and 2 x for the welded PT11.
Is PT12 available in sealed gauge or absolute?
PT12 is gauge only. PT13 uses the same construction in gauge, sealed gauge and absolute, at ±0.5 % or ±1 % of span.
Can the cable length or connector be different?
Yes. Choose the closest option and state the length or connector in the request. It becomes a line on the quote.
Other pressure transmitters
See all 31-
PT10Millivolt pressure sensor, glass-fused cell
0 to 6 up to 0 to 600 bar · 10 to 15 mV/V, four-wire -
PT11Wide-range welded stainless transmitter
0 to 0.2 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT13Glass-fused transmitter, 0.5 % grade
0 to 6 up to 0 to 600 bar · Gauge, sealed gauge, absolute -
PT14Low-range millivolt pressure sensor
0 to 0.4 up to 0 to 70 bar · 10 mV/V, four-wire -
PT15Low-pressure transmitter, vacuum to 6 bar
-1 bar up to 6 bar · 4 to 20 mA or voltage -
PT16Precision transmitter, ±0.1 % of span
0 to 0.4 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT17Ceramic flat-diaphragm pressure transmitter
0 to 2 up to 0 to 25 bar · 4 to 20 mA, voltage or RS485 -
PT18Compact ceramic transmitter for water pumps
0 to 10, 16 or 25 bar · 4 to 20 mA or 0.5 to 4.5 V