Pressure transmitters

Refrigerant pressure sensor with thermistor

Model PT34

Pressure and NTC temperature in one M12 x 1.25 fitting for R410A, R407C and R134a, ratiometric on 5 V DC.

Range
1.01 to 10.25 bar absolute
Accuracy
±2 % of span
Output
Ratiometric, 5 V DC supply
Temperature
-30 to 130 °C, 10 kΩ NTC

Configure PT34

Refrigerant
Order code PT34-010-R410A

No payment now. The quote comes back with the price, the lead time and the documents.

  • Built to the order code you configure
  • Datasheet and dimension drawing with the quote
  • Other ranges and connections quoted on request

PT34 measures refrigerant pressure and temperature at one point. A pressure cell and a 10 kΩ NTC thermistor share one M12 x 1.25 process connection, sealed by an O-ring, and the thermistor sits in a 5.3 mm tip that extends past the thread. It is rated for R410A, R407C and R134a, and is not for media containing sulfur, water or water vapour.

It is a component for builders of air conditioning units. One part takes the place of a separate pressure sensor and temperature sensor on the refrigerant line, with one fitting and one 4-pin connector carrying supply, pressure signal and thermistor. That places it in HVAC and buildings, at the equipment builder rather than on site.

The pressure signal is ratiometric to the 5 V supply, covering 1.01 to 10.25 bar absolute at ±2 % of span with a 10 ms response. The thermistor reads -30 to 130 °C, within ±1.5 °C from -10 to 80 °C and ±3 °C across the full span. Proof pressure is 20 bar absolute and burst pressure 30 bar absolute.

Typical points

  • Pump discharge and suction pressure
  • Hydraulic system pressure on machines
  • Compressed air headers
  • Chilled and heating water circuits

Questions about PT34

Something else? Ask us about this model

How is the pressure signal scaled?

It is ratiometric to the supply: Vout = (0.082878 x P + 5) x Vcc / 100, with P in kPa absolute and Vcc the 5 V DC supply.

Can it go on a water circuit?

No. It is not for media containing sulfur, water or water vapour. It is rated for R410A, R407C and R134a.

Is a higher pressure range possible?

The standard range is 1.01 to 10.25 bar absolute. Choose X in the range field and state the range and refrigerant in the request. It becomes a line on the quote.