Pressure transmitters

Low-power pressure and temperature sensor

Model PT53

Runs on 3 to 5 V DC at 2.5 mA, 0.2 mA standby, with RS485 Modbus RTU or I2C output and ranges to 200 bar.

Supply
3 to 5 V DC, 2.5 mA maximum
Output
RS485 Modbus RTU or I2C
Pressure
0 to 40 kPa up to 0 to 200 bar
Temperature
-20 to 85 °C, ±1 % of span

Configure PT53

Pressure type
Process connection
Output
Order code PT53-K40-G-B2-M-C

No payment now. The quote comes back with the price, the lead time and the documents.

  • Built to the order code you configure
  • Datasheet and dimension drawing with the quote
  • Other ranges and connections quoted on request

PT53 is a pressure and temperature transmitter for sites without mains power. It runs on 3 to 5 V DC and draws 2.5 mA at most, 0.2 mA in standby, which suits loggers and remote units that run from a battery. Pressure and medium temperature come through one process connection and one four-wire cable.

It goes on remote points in water networks and pump stations, and on water, gas or oil lines where only a battery supply is available. That places it in water and pumping first. The 304 stainless steel body is IP65, or IP68 with the sealed cable outlet.

Output is RS485 with Modbus RTU, or I2C. Pressure ranges run from 0 to 40 kPa to 0 to 200 bar, gauge or absolute, at ±0.5 % of span, with 2 x range overload and 3 x range burst. Temperature covers -20 to 85 °C at ±1 % of span. Process threads are G1/4, 1/4 NPT and M20 x 1.5.

Typical points

  • Pump discharge and suction pressure
  • Hydraulic system pressure on machines
  • Compressed air headers
  • Chilled and heating water circuits

Questions about PT53

Something else? Ask us about this model

How much current does it draw?

2.5 mA at most while measuring and 0.2 mA at most in standby, on a 3 to 5 V DC supply.

Which version is IP68?

The sealed cable outlet. The cable outlet and connector versions are IP65.

How does it differ from PT52?

PT52 runs on 9 to 30 V DC, reaches 600 bar and offers ±0.3 % of span. PT53 runs on 3 to 5 V DC at low current, with RS485 Modbus RTU or I2C output.