Analog pressure and temperature transmitter
Pressure up to 600 bar and -30 to 125 °C through one port, as 4 to 20 mA plus Pt100 or two 4 to 20 mA loops.
- Pressure
- 0 to 10 kPa up to 0 to 600 bar
- Temperature
- -30 to 125 °C, Pt100
- Output
- Analog: 2 x 4 to 20 mA or Pt100
- Accuracy
- ±0.3 % or ±0.5 % of span
- Built to the order code you configure
- Datasheet and dimension drawing with the quote
- Other ranges and connections quoted on request
PT50 measures pressure and medium temperature through one process connection, so a single tapping gives both readings. Pressure is sensed by a silicon strain gauge glass-fused to a 17-4PH stainless steel element, in a 304 stainless steel housing. Temperature is sensed by a Pt100 element. Both signals are analog, on a four-wire connection with a 9 to 30 V DC supply.
It goes on pump stations and water treatment plant, hydraulic and pneumatic control systems, and automated test and inspection rigs. That covers water and pumping, hydraulics and machinery, and test benches, wherever one fitting is easier to place than two and the controller takes analog inputs.
Output is 4 to 20 mA for pressure with either the Pt100 wired out directly or a second 4 to 20 mA loop for temperature. Pressure ranges run from 0 to 10 kPa to 0 to 600 bar, gauge or absolute, at ±0.3 % or ±0.5 % of span; temperature reads -30 to 125 °C at ±0.5 % of span. G, NPT, R and metric male threads are offered, IP65.
Typical points
- Pump discharge and suction pressure
- Hydraulic system pressure on machines
- Compressed air headers
- Chilled and heating water circuits
Pressure measurement
| Pressure type | Gauge, absolute |
|---|---|
| Ranges | 0 to 10 kPa up to 0 to 600 bar |
| Accuracy | ±0.3 % or ±0.5 % of span |
| Long-term stability | ±0.1 % of span per year |
| Zero temperature drift | ±0.02 % of span per °C |
| Span temperature drift | ±0.02 % of span per °C |
| Overpressure | 2 x range |
| Burst pressure | 3 x range |
Temperature measurement
| Element | Pt100 |
|---|---|
| Range | -30 to 125 °C |
| Accuracy | ±0.5 % of span |
| Signal | Pt100 wired out, or 4 to 20 mA |
Medium and environment
| Operating temperature | -40 to 85 °C |
|---|---|
| Compensated temperature | -20 to 85 °C |
| Storage temperature | -40 to 125 °C |
| Shock | 100 g, 11 ms |
| Wetted parts | 17-4PH stainless steel |
| Housing | 304 stainless steel |
Electrical
| Output | 4 to 20 mA pressure and Pt100 temperature, or 4 to 20 mA pressure and 4 to 20 mA temperature |
|---|---|
| Wiring | Four-wire |
| Supply | 9 to 30 V DC |
| Electrical connection | Cable outlet, M12 4-pin, DIN 43650 form A or form C, circular or Deutsch DT04-4P connector |
| Protection | IP65 |
Mechanical
| Process connection | G1/8, G1/4, G3/8, G1/2, 1/8 NPT, 1/4 NPT, 1/2 NPT, R1/4, R1/2, M12 x 1.5, M18 x 1.5, M20 x 1.5, male |
|---|---|
| Sensing element | Silicon strain gauge, glass-fused to 17-4PH stainless steel |
| Dimensions | Ø22 mm body, 22 mm hex, 69 mm from thread end to cable gland |
Common configurations. Any combination from the ordering code can be quoted.
| Range | Pressure type | Process connection | Signals | Electrical connection | Accuracy | Order code |
|---|---|---|---|---|---|---|
| 0 to 10 bar | Gauge | G1/4 male | 4 to 20 mA and Pt100 | Cable outlet | ±0.5 % | PT50-010-G-B2-IP-C-A05 |
| 0 to 16 bar | Gauge | G1/2 male | 2 x 4 to 20 mA | M12 | ±0.3 % | PT50-016-G-B4-II-M-A03 |
| 0 to 25 bar | Gauge | 1/4 NPT male | 2 x 4 to 20 mA | DIN 43650 form A | ±0.5 % | PT50-025-G-N2-II-D-A05 |
| 0 to 100 bar | Gauge | M20 x 1.5 male | 4 to 20 mA and Pt100 | M12 | ±0.5 % | PT50-100-G-M20-IP-M-A05 |
| 0 to 250 bar | Gauge | G1/4 male | 2 x 4 to 20 mA | Deutsch DT04-4P | ±0.3 % | PT50-250-G-B2-II-T4-A03 |
| 0 to 1 bar | Absolute | G1/4 male | 2 x 4 to 20 mA | Cable outlet | ±0.5 % | PT50-001-A-B2-II-C-A05 |
One code from each group, in this order. Example: PT50-K10-G-B1-IP-C-A03.
Range
| K10 | 0 to 10 kPa |
|---|---|
| K50 | 0 to 50 kPa |
| 001 | 0 to 1 bar |
| 004 | 0 to 4 bar |
| 010 | 0 to 10 bar |
| 016 | 0 to 16 bar |
| 025 | 0 to 25 bar |
| 060 | 0 to 60 bar |
| 100 | 0 to 100 bar |
| 250 | 0 to 250 bar |
| 600 | 0 to 600 bar |
| X | Other range, state in the request |
Pressure type
| G | Gauge |
|---|---|
| A | Absolute |
Process connection
| B1 | G1/8 male |
|---|---|
| B2 | G1/4 male |
| B3 | G3/8 male |
| B4 | G1/2 male |
| N1 | 1/8 NPT male |
| N2 | 1/4 NPT male |
| N4 | 1/2 NPT male |
| R2 | R1/4 male |
| R4 | R1/2 male |
| M12 | M12 x 1.5 male |
| M18 | M18 x 1.5 male |
| M20 | M20 x 1.5 male |
Output
| IP | 4 to 20 mA pressure and Pt100 temperature |
|---|---|
| II | 4 to 20 mA pressure and 4 to 20 mA temperature |
Electrical connection
| C | Cable outlet |
|---|---|
| M | M12 connector, 4-pin |
| D | DIN 43650 form A connector |
| DC | DIN 43650 form C connector |
| A | Circular connector |
| T4 | Deutsch DT04-4P connector |
Accuracy
| A03 | ±0.3 % of span |
|---|---|
| A05 | ±0.5 % of span |
- DatasheetPDF
- Dimension drawingSent with the quote
- Calibration certificate, per unit on requestSent with the quote
Questions about PT50
Something else? Ask us about this model
What is the difference between the two output options?
With 4 to 20 mA and Pt100, pressure comes as a current loop and the Pt100 goes to a resistance temperature input. With two 4 to 20 mA loops, the transmitter converts temperature as well, for a controller with current inputs only.
How does PT50 differ from PT51 and PT52?
PT50 is analog only and reaches down to 0 to 10 kPa. PT51 adds Modbus, a temperature tip that protrudes from the port and 3 x range overload, from 0 to 6 bar up. PT52 is Modbus only.
Can the process thread be one not listed?
Yes. Choose the nearest thread and state the one you need in the request. It becomes a line on the quote.
Other pressure transmitters
See all 31-
PT10Millivolt pressure sensor, glass-fused cell
0 to 6 up to 0 to 600 bar · 10 to 15 mV/V, four-wire -
PT11Wide-range welded stainless transmitter
0 to 0.2 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT12Glass-fused pressure transmitter, 0.3 % grade
0 to 6 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT13Glass-fused transmitter, 0.5 % grade
0 to 6 up to 0 to 600 bar · Gauge, sealed gauge, absolute -
PT14Low-range millivolt pressure sensor
0 to 0.4 up to 0 to 70 bar · 10 mV/V, four-wire -
PT15Low-pressure transmitter, vacuum to 6 bar
-1 bar up to 6 bar · 4 to 20 mA or voltage -
PT16Precision transmitter, ±0.1 % of span
0 to 0.4 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT17Ceramic flat-diaphragm pressure transmitter
0 to 2 up to 0 to 25 bar · 4 to 20 mA, voltage or RS485