Field housing transmitter with local display
Two-wire 4 to 20 mA loop with a 3.5-digit or pointer display at the point, gauge, sealed gauge or absolute.
- Range
- -1 to 0 bar up to 0 to 600 bar
- Accuracy
- ±0.3 % or ±0.5 % of span
- Output
- 4 to 20 mA, two-wire
- Display
- 3.5-digit or pointer
- Built to the order code you configure
- Datasheet and dimension drawing with the quote
- Other ranges and connections quoted on request
PT70 is a two-wire 4 to 20 mA transmitter in a field housing with a local display, so the operator reads the pressure at the point while the loop carries it to the control system. The display is a 3.5-digit digital readout or an analog pointer, chosen in the order code.
It goes on pump stations, water treatment lines, process pipework and hydraulic units, where a reading at the pipe saves fitting a separate gauge. Ranges run from -1 to 0 bar and from 0 to 0.2 bar up to 0 to 600 bar, gauge, sealed gauge or absolute, with ±0.3 % or ±0.5 % of span accuracy.
Supply is 15 to 30 V DC, 24 V DC recommended. Wetted parts are 304 or 316 stainless steel below 6 bar and 17-4PH stainless steel from 6 bar. Thermal drift is ±0.02 % of span per °C at zero and at span, and frequency response is 3.2 kHz. Protection is IP65.
Typical points
- Pump discharge and suction pressure
- Hydraulic system pressure on machines
- Compressed air headers
- Chilled and heating water circuits
Measurement
| Pressure type | Gauge, sealed gauge, absolute |
|---|---|
| Ranges | -1 to 0 bar; 0 to 0.2 bar up to 0 to 600 bar |
| Accuracy | ±0.3 % or ±0.5 % of span |
| Long-term stability | ±0.1 % of span per year |
| Zero thermal drift | ±0.02 % of span per °C |
| Span thermal drift | ±0.02 % of span per °C |
| Frequency response (-3 dB) | 3.2 kHz |
| Overpressure | 1.5 x range below 6 bar, 3 x range from 6 bar |
| Burst pressure | 3 x range below 6 bar, 5 x range from 6 bar |
Medium and environment
| Compensated temperature | -20 to 85 °C |
|---|---|
| Operating temperature | -40 to 85 °C; display head -20 to 85 °C |
| Storage temperature | -40 to 125 °C |
| Vibration | ±20 g |
| Shock | 100 g, 11 ms |
| Wetted parts | 304 or 316 stainless steel below 6 bar, 17-4PH stainless steel from 6 bar |
Electrical
| Output | 4 to 20 mA, two-wire |
|---|---|
| Supply | 15 to 30 V DC, 24 V DC recommended |
| Electrical connection | Cable gland on the housing |
| Protection | IP65 |
Display
| Display | 3.5-digit digital display or analog pointer |
|---|
Mechanical
| Process connection | M20 x 1.5, G1/4, 1/4 NPT; other threads on request |
|---|
Common configurations. Any combination from the ordering code can be quoted.
| Range | Pressure type | Process connection | Display | Accuracy | Order code |
|---|---|---|---|---|---|
| 0 to 10 bar | Gauge | M20 x 1.5 male | Digital | ±0.5 % | PT70-010-G-M20-DG-A05 |
| 0 to 16 bar | Gauge | G1/4 male | Digital | ±0.3 % | PT70-016-G-B2-DG-A03 |
| -1 to 0 bar | Gauge | M20 x 1.5 male | Digital | ±0.5 % | PT70-V00-G-M20-DG-A05 |
| 0 to 1 bar | Absolute | G1/4 male | Digital | ±0.3 % | PT70-001-A-B2-DG-A03 |
| 0 to 25 bar | Sealed gauge | 1/4 NPT male | Pointer | ±0.5 % | PT70-025-S-N2-AN-A05 |
| 0 to 250 bar | Sealed gauge | M20 x 1.5 male | Digital | ±0.5 % | PT70-250-S-M20-DG-A05 |
One code from each group, in this order. Example: PT70-V00-G-M20-DG-A03.
Range
| V00 | -1 to 0 bar |
|---|---|
| K20 | 0 to 20 kPa |
| 001 | 0 to 1 bar |
| 006 | 0 to 6 bar |
| 010 | 0 to 10 bar |
| 016 | 0 to 16 bar |
| 025 | 0 to 25 bar |
| 100 | 0 to 100 bar |
| 250 | 0 to 250 bar |
| 600 | 0 to 600 bar |
| X | Other range, state in the request |
Pressure type
| G | Gauge |
|---|---|
| S | Sealed gauge |
| A | Absolute |
Process connection
| M20 | M20 x 1.5 male |
|---|---|
| B2 | G1/4 male |
| N2 | 1/4 NPT male |
Display
| DG | 3.5-digit digital display |
|---|---|
| AN | Analog pointer display |
Accuracy
| A03 | ±0.3 % of span |
|---|---|
| A05 | ±0.5 % of span |
- DatasheetPDF
- Dimension drawingSent with the quote
- Calibration certificate, per unit on requestSent with the quote
Questions about PT70
Something else? Ask us about this model
Digital display or pointer?
Both are offered: a 3.5-digit digital display or an analog pointer. Choose it in the order code; the loop output is 4 to 20 mA either way.
Which material touches the medium?
Ranges below 6 bar have 304 or 316 stainless steel wetted parts. From 6 bar the wetted parts are 17-4PH stainless steel.
My range is not in the list. Can it be supplied?
Any range from -1 to 0 bar, or from 0 to 0.2 bar up to 0 to 600 bar. Choose X, state the range in the request and it becomes a line on the quote.
Other pressure transmitters
See all 31-
PT10Millivolt pressure sensor, glass-fused cell
0 to 6 up to 0 to 600 bar · 10 to 15 mV/V, four-wire -
PT11Wide-range welded stainless transmitter
0 to 0.2 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT12Glass-fused pressure transmitter, 0.3 % grade
0 to 6 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT13Glass-fused transmitter, 0.5 % grade
0 to 6 up to 0 to 600 bar · Gauge, sealed gauge, absolute -
PT14Low-range millivolt pressure sensor
0 to 0.4 up to 0 to 70 bar · 10 mV/V, four-wire -
PT15Low-pressure transmitter, vacuum to 6 bar
-1 bar up to 6 bar · 4 to 20 mA or voltage -
PT16Precision transmitter, ±0.1 % of span
0 to 0.4 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT17Ceramic flat-diaphragm pressure transmitter
0 to 2 up to 0 to 25 bar · 4 to 20 mA, voltage or RS485