Barometric pressure transmitter, wall mount
Air pressure transmitter, 30 to 120 kPa absolute, with 4 to 20 mA, 0 to 5 V, 0 to 10 V or RS485 Modbus output.
- Range
- 30 to 120 kPa absolute
- Accuracy
- ±0.15 kPa at 25 °C
- Output
- Analog or RS485 Modbus RTU
- Supply
- 10 to 30 V DC
- Built to the order code you configure
- Datasheet and dimension drawing with the quote
- Other ranges and connections quoted on request
PT80 measures atmospheric pressure from 30 to 120 kPa absolute, which covers weather at sea level and sites at altitude. It sits in a wall-mount housing of 122 by 100 mm, with a slotted probe tube and a cable gland on the underside and two mounting lugs at the sides.
It gives the barometric reference that building management, greenhouse and ventilation controllers work from, and the ambient pressure that test benches use to correct flow, engine and leak measurements to reference conditions. On wells and reservoirs it provides the barometric reading for compensating absolute level probes.
Accuracy is ±0.15 kPa at 25 °C, resolution 0.012 mbar and response time 1 s or less. Outputs are 4 to 20 mA, 0 to 5 V or 0 to 10 V, or RS485 with Modbus RTU, addresses 1 to 255 and baud rates from 2400 to 115200. Supply is 10 to 30 V DC; the 0 to 10 V version is limited to 24 V DC.
Typical points
- Pump discharge and suction pressure
- Hydraulic system pressure on machines
- Compressed air headers
- Chilled and heating water circuits
Measurement
| Pressure type | Absolute, barometric |
|---|---|
| Range | 30 to 120 kPa |
| Accuracy | ±0.15 kPa at 25 °C |
| Resolution | 0.012 mbar |
| Long-term stability | 0.1 kPa per year |
| Response time | 1 s or less |
Medium and environment
| Medium | Ambient air |
|---|---|
| Operating temperature | -20 to 60 °C |
Electrical
| Output | 4 to 20 mA, 0 to 5 V, 0 to 10 V or RS485 Modbus RTU |
|---|---|
| Supply | 10 to 30 V DC; 0 to 10 V output limited to 24 V DC |
| Power consumption | 1.2 W analog, 0.4 W RS485 |
| Electrical connection | Cable outlet |
Communication
| Protocol | Modbus RTU over RS485 |
|---|---|
| Address | 1 to 255, default 1 |
| Baud rate | 2400, 4800, 9600, 19200, 38400, 57600 or 115200; default 9600 |
| Data format | 8 data bits, no parity, 1 stop bit |
Mechanical
| Housing | Wall mount, 122 x 100 mm |
|---|---|
| Mounting | Two 4.3 mm holes, 110 mm apart |
Common configurations. Any combination from the ordering code can be quoted.
| Range | Output | Supply | Order code |
|---|---|---|---|
| 30 to 120 kPa | 4 to 20 mA | 10 to 30 V DC | PT80-K120-I |
| 30 to 120 kPa | 0 to 5 V | 10 to 30 V DC | PT80-K120-V5 |
| 30 to 120 kPa | 0 to 10 V | 10 to 24 V DC | PT80-K120-V10 |
| 30 to 120 kPa | RS485 Modbus RTU | 10 to 30 V DC | PT80-K120-M |
One code from each group, in this order. Example: PT80-K120-I.
Range
| K120 | 30 to 120 kPa absolute |
|---|---|
| X | Other range, state in the request |
Output
| I | 4 to 20 mA |
|---|---|
| V5 | 0 to 5 V |
| V10 | 0 to 10 V |
| M | RS485 Modbus RTU |
- DatasheetPDF
- Dimension drawingSent with the quote
- Calibration certificate, per unit on requestSent with the quote
Questions about PT80
Something else? Ask us about this model
Which Modbus settings does the RS485 version use?
Address 1 to 255, default 1. Baud rate 2400 to 115200, default 9600. Data format is 8 data bits, no parity, 1 stop bit.
Does it work at altitude?
Yes. The 30 to 120 kPa range covers sites well above sea level as well as high-pressure weather at sea level.
Can it measure pipe or vessel pressure?
No. PT80 reads ambient air pressure only. For pipes, vessels and machines, choose one of the threaded transmitters in this family.
Other pressure transmitters
See all 31-
PT10Millivolt pressure sensor, glass-fused cell
0 to 6 up to 0 to 600 bar · 10 to 15 mV/V, four-wire -
PT11Wide-range welded stainless transmitter
0 to 0.2 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT12Glass-fused pressure transmitter, 0.3 % grade
0 to 6 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT13Glass-fused transmitter, 0.5 % grade
0 to 6 up to 0 to 600 bar · Gauge, sealed gauge, absolute -
PT14Low-range millivolt pressure sensor
0 to 0.4 up to 0 to 70 bar · 10 mV/V, four-wire -
PT15Low-pressure transmitter, vacuum to 6 bar
-1 bar up to 6 bar · 4 to 20 mA or voltage -
PT16Precision transmitter, ±0.1 % of span
0 to 0.4 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT17Ceramic flat-diaphragm pressure transmitter
0 to 2 up to 0 to 25 bar · 4 to 20 mA, voltage or RS485