Digital pressure and temperature transmitter
Pressure and temperature over Modbus RTU on RS485 or RS232, 0 to 10 kPa up to 0 to 600 bar, 9 to 30 V DC.
- Pressure
- 0 to 10 kPa up to 0 to 600 bar
- Temperature
- -30 to 125 °C, ±1 % of span
- Output
- RS485 or RS232 Modbus RTU
- Accuracy
- ±0.3 % or ±0.5 % of span
- Built to the order code you configure
- Datasheet and dimension drawing with the quote
- Other ranges and connections quoted on request
PT52 is the digital pressure and temperature transmitter in the range. One four-wire connection carries supply and both readings, pressure and medium temperature, over Modbus RTU on RS485, or on RS232 for a point-to-point link. There is no analog scaling to set in the controller, and both readings share one cable and one process tapping.
It goes on pump stations and water treatment works, hydraulic and pneumatic units, and automated test stations, where readings go straight into a PLC or SCADA system over a serial link. That covers water and pumping, hydraulics and machinery, and test benches.
Pressure ranges run from 0 to 10 kPa to 0 to 600 bar, gauge or absolute, at ±0.3 % or ±0.5 % of span, with 2 x range overload. Temperature covers -30 to 125 °C at ±1 % of span. The 17-4PH stainless steel sensing element sits in a 304 stainless steel housing, IP65, with cable outlet, M12, DIN 43650, circular or Deutsch DT04-4P connection.
Typical points
- Pump discharge and suction pressure
- Hydraulic system pressure on machines
- Compressed air headers
- Chilled and heating water circuits
Pressure measurement
| Pressure type | Gauge, absolute |
|---|---|
| Ranges | 0 to 10 kPa up to 0 to 600 bar |
| Accuracy | ±0.3 % or ±0.5 % of span |
| Long-term stability | ±0.1 % of span per year |
| Zero temperature drift | ±0.02 % of span per °C |
| Span temperature drift | ±0.02 % of span per °C |
| Overpressure | 2 x range |
| Burst pressure | 3 x range |
Temperature measurement
| Range | -30 to 125 °C |
|---|---|
| Accuracy | ±1 % of span |
| Signal | Modbus RTU, with the pressure reading |
Medium and environment
| Operating temperature | -40 to 85 °C |
|---|---|
| Compensated temperature | -20 to 85 °C |
| Storage temperature | -40 to 125 °C |
| Shock | 100 g, 11 ms |
| Wetted parts | 17-4PH stainless steel |
| Housing | 304 stainless steel |
Electrical
| Output | RS485 or RS232, Modbus RTU |
|---|---|
| Wiring | Four-wire |
| Supply | 9 to 30 V DC |
| Electrical connection | Cable outlet, M12 4-pin, DIN 43650 form A or form C, circular or Deutsch DT04-4P connector |
| Protection | IP65 |
Mechanical
| Process connection | G1/8, G1/4, G3/8, G1/2, 1/8 NPT, 1/4 NPT, 1/2 NPT, R1/4, R1/2, M12 x 1.5, M18 x 1.5, M20 x 1.5, male |
|---|---|
| Dimensions | Ø22 mm body, 22 mm hex, 69 mm from thread end to cable gland |
Common configurations. Any combination from the ordering code can be quoted.
| Range | Pressure type | Process connection | Output | Electrical connection | Accuracy | Order code |
|---|---|---|---|---|---|---|
| 0 to 10 bar | Gauge | G1/4 male | RS485 Modbus RTU | M12 | ±0.5 % | PT52-010-G-B2-M-M-A05 |
| 0 to 16 bar | Gauge | G1/2 male | RS485 Modbus RTU | Cable outlet | ±0.3 % | PT52-016-G-B4-M-C-A03 |
| 0 to 25 bar | Gauge | 1/4 NPT male | RS485 Modbus RTU | DIN 43650 form A | ±0.5 % | PT52-025-G-N2-M-D-A05 |
| 0 to 100 bar | Gauge | M20 x 1.5 male | RS485 Modbus RTU | M12 | ±0.3 % | PT52-100-G-M20-M-M-A03 |
| 0 to 250 bar | Gauge | G1/4 male | RS485 Modbus RTU | Deutsch DT04-4P | ±0.5 % | PT52-250-G-B2-M-T4-A05 |
| 0 to 1 bar | Absolute | G1/4 male | RS232 Modbus RTU | Cable outlet | ±0.5 % | PT52-001-A-B2-M2-C-A05 |
One code from each group, in this order. Example: PT52-K10-G-B1-M-C-A03.
Range
| K10 | 0 to 10 kPa |
|---|---|
| K50 | 0 to 50 kPa |
| 001 | 0 to 1 bar |
| 004 | 0 to 4 bar |
| 010 | 0 to 10 bar |
| 016 | 0 to 16 bar |
| 025 | 0 to 25 bar |
| 060 | 0 to 60 bar |
| 100 | 0 to 100 bar |
| 250 | 0 to 250 bar |
| 600 | 0 to 600 bar |
| X | Other range, state in the request |
Pressure type
| G | Gauge |
|---|---|
| A | Absolute |
Process connection
| B1 | G1/8 male |
|---|---|
| B2 | G1/4 male |
| B3 | G3/8 male |
| B4 | G1/2 male |
| N1 | 1/8 NPT male |
| N2 | 1/4 NPT male |
| N4 | 1/2 NPT male |
| R2 | R1/4 male |
| R4 | R1/2 male |
| M12 | M12 x 1.5 male |
| M18 | M18 x 1.5 male |
| M20 | M20 x 1.5 male |
Output
| M | RS485, Modbus RTU |
|---|---|
| M2 | RS232, Modbus RTU |
Electrical connection
| C | Cable outlet |
|---|---|
| M | M12 connector, 4-pin |
| D | DIN 43650 form A connector |
| DC | DIN 43650 form C connector |
| A | Circular connector |
| T4 | Deutsch DT04-4P connector |
Accuracy
| A03 | ±0.3 % of span |
|---|---|
| A05 | ±0.5 % of span |
- DatasheetPDF
- Dimension drawingSent with the quote
Questions about PT52
Something else? Ask us about this model
Which serial interfaces are offered?
RS485 or RS232, both with Modbus RTU. State the interface on the order with the output code.
Can I get an analog signal instead?
Not from this model. PT50 gives 4 to 20 mA with a Pt100 or a second 4 to 20 mA loop, and PT51 offers both analog and Modbus versions.
Other pressure transmitters
See all 31-
PT10Millivolt pressure sensor, glass-fused cell
0 to 6 up to 0 to 600 bar · 10 to 15 mV/V, four-wire -
PT11Wide-range welded stainless transmitter
0 to 0.2 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT12Glass-fused pressure transmitter, 0.3 % grade
0 to 6 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT13Glass-fused transmitter, 0.5 % grade
0 to 6 up to 0 to 600 bar · Gauge, sealed gauge, absolute -
PT14Low-range millivolt pressure sensor
0 to 0.4 up to 0 to 70 bar · 10 mV/V, four-wire -
PT15Low-pressure transmitter, vacuum to 6 bar
-1 bar up to 6 bar · 4 to 20 mA or voltage -
PT16Precision transmitter, ±0.1 % of span
0 to 0.4 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT17Ceramic flat-diaphragm pressure transmitter
0 to 2 up to 0 to 25 bar · 4 to 20 mA, voltage or RS485