Ultra-high pressure transmitter to 6000 bar
Amplified transmitter for 750 to 6000 bar with 4 to 20 mA or voltage output and a one-piece 17-4PH chamber.
- Range
- 0 to 750 up to 0 to 6000 bar
- Accuracy
- ±0.3 or ±0.5 % of span
- Output
- 4 to 20 mA or voltage
- Protection
- IP65
- Built to the order code you configure
- Datasheet and dimension drawing with the quote
- Other ranges and connections quoted on request
PT21 is the amplified transmitter for ranges from 0 to 750 bar up to 0 to 6000 bar. It gives 4 to 20 mA on two wires, or 0.5 to 4.5 V, 0 to 5 V or 0 to 10 V on three wires, and connects straight to a PLC, controller or panel display with no separate amplifier.
It goes on waterjet cutting and high-pressure cleaning pumps, hydraulic intensifiers and presses, and test benches for high-pressure hoses, valves and fittings. Allowed overload is 1.5 x range and burst pressure 3 x range, 10000 bar at most. Temperature compensation covers -20 to 85 °C.
Silicon strain gauges are glass-fused to a pressure chamber machined from one piece of 17-4PH stainless steel, with no welds and no O-rings in contact with the medium. The M20 x 1.5 port seals on its end face with a copper gasket; G, NPT and R threads are also offered. Electrical options run from DIN 43650 and M12 to Packard, AMP and Deutsch connectors.
Typical points
- Pump discharge and suction pressure
- Hydraulic system pressure on machines
- Compressed air headers
- Chilled and heating water circuits
Measurement
| Pressure type | Gauge |
|---|---|
| Ranges | 0 to 750 bar up to 0 to 6000 bar |
| Accuracy | ±0.3 % or ±0.5 % of span |
| Overpressure | 1.5 x range |
| Burst pressure | 3 x range, 10000 bar at most |
| Long-term stability | ±0.2 % of span per year |
| Zero drift | ±0.02 % of span per °C |
| Span drift | ±0.02 % of span per °C |
| Compensated range | -20 to 85 °C |
Medium and environment
| Medium temperature | -40 to 85 °C |
|---|---|
| Storage temperature | -40 to 125 °C |
| Shock | 100 g, 11 ms |
| Wetted parts | 17-4PH stainless steel |
| Housing | Stainless steel 304 |
Electrical
| Output | 4 to 20 mA two-wire; 0.5 to 4.5 V, 0 to 5 V or 0 to 10 V three-wire |
|---|---|
| Supply | 9 to 30 V DC (4 to 20 mA, 0 to 5 V); 5 V DC (0.5 to 4.5 V); 15 to 30 V DC (0 to 10 V) |
| Circuit protection | Reverse polarity and surge |
| Electrical connection | DIN 43650 form A or form C, M12, Packard, circular connector, AMP, Deutsch DT04 3 or 4 pin, cable outlet or sealed cable outlet |
| Protection | IP65 |
Mechanical
| Process connection | M20 x 1.5, M18 x 1.5, M12 x 1.5, G1/8 to G1/2, 1/8 to 1/2 NPT, R1/8 to R1/2 male |
|---|---|
| Body | 22 mm diameter, 22 mm hex |
| Sensing element | Silicon strain gauges glass-fused to a one-piece 17-4PH stainless steel body, no welds or O-rings |
Common configurations. Any combination from the ordering code can be quoted.
| Range | Accuracy | Process connection | Output | Electrical connection | Order code |
|---|---|---|---|---|---|
| 0 to 750 bar | ±0.5 % of span | M20 x 1.5 male | 4 to 20 mA | M12 connector | PT21-750-A05-M20-I-M |
| 0 to 1000 bar | ±0.5 % of span | G1/2 male | 4 to 20 mA | DIN 43650 form A | PT21-1000-A05-B4-I-D |
| 0 to 1600 bar | ±0.3 % of span | M20 x 1.5 male | 0 to 10 V | M12 connector | PT21-1600-A03-M20-V10-M |
| 0 to 2500 bar | ±0.5 % of span | M20 x 1.5 male | 0.5 to 4.5 V | Packard | PT21-2500-A05-M20-H-P |
| 0 to 4000 bar | ±0.3 % of span | M20 x 1.5 male | 4 to 20 mA | Cable outlet | PT21-4000-A03-M20-I-C |
| 0 to 6000 bar | ±0.5 % of span | M20 x 1.5 male | 4 to 20 mA | Sealed cable outlet | PT21-6000-A05-M20-I-CW |
One code from each group, in this order. Example: PT21-750-A03-M20-I-D.
Range
| 750 | 0 to 750 bar |
|---|---|
| 1000 | 0 to 1000 bar |
| 1600 | 0 to 1600 bar |
| 2500 | 0 to 2500 bar |
| 4000 | 0 to 4000 bar |
| 6000 | 0 to 6000 bar |
| X | Other range, state in the request |
Accuracy
| A03 | ±0.3 % of span |
|---|---|
| A05 | ±0.5 % of span |
Process connection
| M20 | M20 x 1.5 male |
|---|---|
| M12 | M12 x 1.5 male |
| B4 | G1/2 male |
| B3 | G3/8 male |
| B2 | G1/4 male |
| B1 | G1/8 male |
| N4 | 1/2 NPT male |
| N2 | 1/4 NPT male |
| N1 | 1/8 NPT male |
Output
| I | 4 to 20 mA, two-wire |
|---|---|
| H | 0.5 to 4.5 V, three-wire |
| V5 | 0 to 5 V, three-wire |
| V10 | 0 to 10 V, three-wire |
Electrical connection
| D | DIN 43650 form A connector |
|---|---|
| DC | DIN 43650 form C connector |
| M | M12 connector, 4-pin |
| P | Packard connector |
| A | Circular connector, 5-pin |
| AM | AMP connector, 2-pin, 4 to 20 mA only |
| T3 | Deutsch DT04-3P |
| T4 | Deutsch DT04-4P |
| C | Cable outlet |
| CW | Sealed cable outlet |
- DatasheetPDF
- Dimension drawingSent with the quote
- Calibration certificate, per unit on requestSent with the quote
Questions about PT21
Something else? Ask us about this model
What supply does each output need?
4 to 20 mA and 0 to 5 V run on 9 to 30 V DC, 0 to 10 V on 15 to 30 V DC, and 0.5 to 4.5 V on 5 V DC.
Is my thread in the list?
The order code covers the common G, NPT and metric threads. R1/8 to R1/2, 3/8 NPT and M18 x 1.5 are also available: state the thread in the request and it becomes a line on the quote.
Other pressure transmitters
See all 31-
PT10Millivolt pressure sensor, glass-fused cell
0 to 6 up to 0 to 600 bar · 10 to 15 mV/V, four-wire -
PT11Wide-range welded stainless transmitter
0 to 0.2 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT12Glass-fused pressure transmitter, 0.3 % grade
0 to 6 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT13Glass-fused transmitter, 0.5 % grade
0 to 6 up to 0 to 600 bar · Gauge, sealed gauge, absolute -
PT14Low-range millivolt pressure sensor
0 to 0.4 up to 0 to 70 bar · 10 mV/V, four-wire -
PT15Low-pressure transmitter, vacuum to 6 bar
-1 bar up to 6 bar · 4 to 20 mA or voltage -
PT16Precision transmitter, ±0.1 % of span
0 to 0.4 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT17Ceramic flat-diaphragm pressure transmitter
0 to 2 up to 0 to 25 bar · 4 to 20 mA, voltage or RS485