Pressure-temperature transmitter, probe tip
Platinum element in a tip past the thread, 0 to 6 up to 0 to 600 bar, Modbus RTU or 4 to 20 mA output.
- Pressure
- 0 to 6 bar up to 0 to 600 bar
- Temperature
- -30 to 125 °C, probe tip
- Output
- Modbus RTU or 4 to 20 mA
- Overload
- 3 x range, burst 5 x range
- Built to the order code you configure
- Datasheet and dimension drawing with the quote
- Other ranges and connections quoted on request
PT51 reads pressure and medium temperature through one port. Its platinum temperature element sits in a 5 mm probe that protrudes 5 mm beyond the process thread, in the medium itself rather than behind the port, which gives a fast temperature response. Pressure is measured on a 17-4PH stainless steel element in a 304 stainless steel housing.
The pressure element takes 3 x range overload and 5 x range before burst, which suits hydraulic and pneumatic circuits with pressure peaks. It also goes on pump stations and water treatment plant and on automated test systems, covering hydraulics and machinery, water and pumping, and test benches.
Output is RS485 or RS232 with Modbus RTU, or analog: 4 to 20 mA for pressure with the platinum element wired out, or a second 4 to 20 mA loop for temperature. Pressure ranges run from 0 to 6 bar to 0 to 600 bar, gauge or absolute, at ±0.3 % or ±0.5 % of span. Temperature reads -30 to 125 °C within ±0.5 % of span or ±0.5 °C, whichever is greater.
Typical points
- Pump discharge and suction pressure
- Hydraulic system pressure on machines
- Compressed air headers
- Chilled and heating water circuits
Pressure measurement
| Pressure type | Gauge, absolute |
|---|---|
| Ranges | 0 to 6 bar up to 0 to 600 bar |
| Accuracy | ±0.3 % or ±0.5 % of span |
| Long-term stability | ±0.1 % of span per year |
| Zero temperature drift | ±0.02 % of span per °C |
| Span temperature drift | ±0.02 % of span per °C |
| Overpressure | 3 x range |
| Burst pressure | 5 x range |
Temperature measurement
| Element | Platinum resistance in a protruding probe tip |
|---|---|
| Probe tip | Ø5 mm, 5 mm beyond the thread |
| Range | -30 to 125 °C |
| Accuracy | ±0.5 % of span or ±0.5 °C, whichever is greater |
| Signal | Modbus RTU, platinum element wired out, or 4 to 20 mA |
Medium and environment
| Operating temperature | -40 to 85 °C |
|---|---|
| Compensated temperature | -20 to 85 °C |
| Storage temperature | -40 to 125 °C |
| Shock | 100 g, 11 ms |
| Wetted parts | 17-4PH stainless steel |
| Housing | 304 stainless steel |
Electrical
| Output | RS485 or RS232 Modbus RTU; 4 to 20 mA pressure and platinum element; or 4 to 20 mA pressure and 4 to 20 mA temperature |
|---|---|
| Wiring | Four-wire |
| Supply | 9 to 30 V DC |
| Electrical connection | Cable outlet, M12 4-pin, DIN 43650 form A or form C, circular or Deutsch DT04-4P connector |
| Protection | IP65 |
Mechanical
| Process connection | G1/8, G1/4, G3/8, G1/2, 1/8 NPT, 1/4 NPT, 1/2 NPT, R1/4, R1/2, M12 x 1.5, M18 x 1.5, M20 x 1.5, male |
|---|---|
| Dimensions | Ø22 mm body, 22 mm hex, 74 mm from cable gland to probe tip |
Common configurations. Any combination from the ordering code can be quoted.
| Range | Pressure type | Process connection | Signals | Electrical connection | Accuracy | Order code |
|---|---|---|---|---|---|---|
| 0 to 10 bar | Gauge | G1/4 male | RS485 Modbus RTU | M12 | ±0.5 % | PT51-010-G-B2-M-M-A05 |
| 0 to 16 bar | Gauge | G1/2 male | 4 to 20 mA and platinum element | Cable outlet | ±0.3 % | PT51-016-G-B4-IP-C-A03 |
| 0 to 25 bar | Gauge | 1/4 NPT male | 2 x 4 to 20 mA | DIN 43650 form A | ±0.5 % | PT51-025-G-N2-II-D-A05 |
| 0 to 100 bar | Gauge | M20 x 1.5 male | RS485 Modbus RTU | Cable outlet | ±0.3 % | PT51-100-G-M20-M-C-A03 |
| 0 to 250 bar | Gauge | G1/4 male | 2 x 4 to 20 mA | Deutsch DT04-4P | ±0.5 % | PT51-250-G-B2-II-T4-A05 |
| 0 to 6 bar | Absolute | G1/4 male | RS232 Modbus RTU | M12 | ±0.5 % | PT51-006-A-B2-M2-M-A05 |
One code from each group, in this order. Example: PT51-006-G-B1-M-C-A03.
Range
| 006 | 0 to 6 bar |
|---|---|
| 010 | 0 to 10 bar |
| 016 | 0 to 16 bar |
| 025 | 0 to 25 bar |
| 040 | 0 to 40 bar |
| 060 | 0 to 60 bar |
| 100 | 0 to 100 bar |
| 160 | 0 to 160 bar |
| 250 | 0 to 250 bar |
| 400 | 0 to 400 bar |
| 600 | 0 to 600 bar |
| X | Other range, state in the request |
Pressure type
| G | Gauge |
|---|---|
| A | Absolute |
Process connection
| B1 | G1/8 male |
|---|---|
| B2 | G1/4 male |
| B3 | G3/8 male |
| B4 | G1/2 male |
| N1 | 1/8 NPT male |
| N2 | 1/4 NPT male |
| N4 | 1/2 NPT male |
| R2 | R1/4 male |
| R4 | R1/2 male |
| M12 | M12 x 1.5 male |
| M18 | M18 x 1.5 male |
| M20 | M20 x 1.5 male |
Output
| M | RS485, Modbus RTU |
|---|---|
| M2 | RS232, Modbus RTU |
| IP | 4 to 20 mA pressure and platinum element temperature |
| II | 4 to 20 mA pressure and 4 to 20 mA temperature |
Electrical connection
| C | Cable outlet |
|---|---|
| M | M12 connector, 4-pin |
| D | DIN 43650 form A connector |
| DC | DIN 43650 form C connector |
| A | Circular connector |
| T4 | Deutsch DT04-4P connector |
Accuracy
| A03 | ±0.3 % of span |
|---|---|
| A05 | ±0.5 % of span |
- DatasheetPDF
- Dimension drawingSent with the quote
- Calibration certificate, per unit on requestSent with the quote
Questions about PT51
Something else? Ask us about this model
Why does the temperature probe protrude?
The platinum element sits in a 5 mm tip that extends 5 mm past the thread, in the medium itself. That gives a fast temperature response.
Which digital interfaces are offered?
RS485 or RS232, both with Modbus RTU, four-wire on a 9 to 30 V DC supply. Analog versions give 4 to 20 mA for pressure with the platinum element or a second 4 to 20 mA loop.
How does PT51 differ from PT50?
PT51 starts at 0 to 6 bar, takes 3 x range overload instead of 2 x, has the protruding probe tip and adds Modbus. PT50 reaches down to 0 to 10 kPa with analog signals only.
Other pressure transmitters
See all 31-
PT10Millivolt pressure sensor, glass-fused cell
0 to 6 up to 0 to 600 bar · 10 to 15 mV/V, four-wire -
PT11Wide-range welded stainless transmitter
0 to 0.2 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT12Glass-fused pressure transmitter, 0.3 % grade
0 to 6 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT13Glass-fused transmitter, 0.5 % grade
0 to 6 up to 0 to 600 bar · Gauge, sealed gauge, absolute -
PT14Low-range millivolt pressure sensor
0 to 0.4 up to 0 to 70 bar · 10 mV/V, four-wire -
PT15Low-pressure transmitter, vacuum to 6 bar
-1 bar up to 6 bar · 4 to 20 mA or voltage -
PT16Precision transmitter, ±0.1 % of span
0 to 0.4 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT17Ceramic flat-diaphragm pressure transmitter
0 to 2 up to 0 to 25 bar · 4 to 20 mA, voltage or RS485