Modbus pressure transmitter, RS485 or RS232
Digital output for PLC networks and test benches, 0 to 0.2 bar up to 0 to 600 bar, gauge or absolute.
- Range
- 0 to 0.2 bar up to 0 to 600 bar
- Accuracy
- ±0.3 % or ±0.5 % of span
- Output
- Modbus on RS485 or RS232
- Protection
- IP65
- Built to the order code you configure
- Datasheet and dimension drawing with the quote
- Other ranges and connections quoted on request
PT40 is a digital pressure transmitter that reports over Modbus, on RS485 or RS232, instead of an analog signal. A MEMS sensing element is glass micro-fused to a pressure chamber machined from one piece of stainless steel, with no weld seam and no O-ring in contact with the medium. Temperature effects are compensated digitally from -20 to 85 °C.
It suits points where several instruments share one cable back to a PLC or data logger: hydraulic units and machines, test benches that log many channels, and pump skids already wired for RS485. Ranges run from 0 to 0.2 bar up to 0 to 600 bar, gauge or absolute, with ±0.3 % or ±0.5 % of span accuracy.
Supply is 9 to 30 V DC. The electrical connection is a cable outlet, an M12 connector or a DIN 43650 form A connector, and the process connection is M20 x 1.5, G1/4 or 1/4 NPT. Ranges from 6 bar take 3 x range overpressure and 5 x range burst pressure.
Typical points
- Pump discharge and suction pressure
- Hydraulic system pressure on machines
- Compressed air headers
- Chilled and heating water circuits
Measurement
| Pressure type | Gauge, absolute |
|---|---|
| Ranges | 0 to 0.2 bar up to 0 to 600 bar |
| Accuracy | ±0.3 % or ±0.5 % of span |
| Long-term stability | ±0.1 % of span per year |
| Overpressure | 1.5 x range below 6 bar, 3 x range from 6 bar |
| Burst pressure | 3 x range below 6 bar, 5 x range from 6 bar |
| Sensing element | MEMS, glass micro-fused |
Medium and environment
| Compensated temperature | -20 to 85 °C |
|---|---|
| Operating temperature | -40 to 85 °C |
| Storage temperature | -40 to 125 °C |
| Shock | 100 g, 11 ms |
| Wetted parts | 304 or 316 stainless steel below 6 bar, 17-4PH stainless steel from 6 bar |
Electrical
| Output | RS485 or RS232, Modbus protocol |
|---|---|
| Supply | 9 to 30 V DC |
| Electrical connection | Cable outlet, M12 connector or DIN 43650 form A connector |
| Protection | IP65 |
Mechanical
| Process connection | M20 x 1.5, G1/4, 1/4 NPT; other threads on request |
|---|---|
| Pressure chamber | Machined from one piece, no weld seam, no O-ring |
Common configurations. Any combination from the ordering code can be quoted.
| Range | Pressure type | Process connection | Output | Electrical connection | Accuracy | Order code |
|---|---|---|---|---|---|---|
| 0 to 10 bar | Gauge | G1/4 male | RS485 | M12 | ±0.5 % | PT40-010-G-B2-M-M-A05 |
| 0 to 25 bar | Gauge | G1/4 male | RS485 | Cable outlet | ±0.3 % | PT40-025-G-B2-M-C-A03 |
| 0 to 250 bar | Gauge | M20 x 1.5 male | RS485 | DIN 43650 form A | ±0.5 % | PT40-250-G-M20-M-D-A05 |
| 0 to 600 bar | Gauge | M20 x 1.5 male | RS485 | M12 | ±0.5 % | PT40-600-G-M20-M-M-A05 |
| 0 to 1 bar | Absolute | G1/4 male | RS485 | M12 | ±0.3 % | PT40-001-A-B2-M-M-A03 |
| 0 to 16 bar | Gauge | 1/4 NPT male | RS232 | Cable outlet | ±0.5 % | PT40-016-G-N2-M2-C-A05 |
One code from each group, in this order. Example: PT40-K20-G-M20-M-C-A03.
Range
| K20 | 0 to 20 kPa |
|---|---|
| 001 | 0 to 1 bar |
| 006 | 0 to 6 bar |
| 010 | 0 to 10 bar |
| 016 | 0 to 16 bar |
| 025 | 0 to 25 bar |
| 100 | 0 to 100 bar |
| 250 | 0 to 250 bar |
| 600 | 0 to 600 bar |
| X | Other range, state in the request |
Pressure type
| G | Gauge |
|---|---|
| A | Absolute |
Process connection
| M20 | M20 x 1.5 male |
|---|---|
| B2 | G1/4 male |
| N2 | 1/4 NPT male |
Output
| M | RS485, Modbus |
|---|---|
| M2 | RS232, Modbus |
Electrical connection
| C | Cable outlet |
|---|---|
| M | M12 connector |
| D | DIN 43650 form A connector |
Accuracy
| A03 | ±0.3 % of span |
|---|---|
| A05 | ±0.5 % of span |
- DatasheetPDF
- Dimension drawingSent with the quote
Questions about PT40
Something else? Ask us about this model
RS485 or RS232?
Both carry Modbus. RS485 runs several transmitters on one pair over long cable; RS232 is a point-to-point link to one device. Choose it in the order code.
How much overpressure does it take?
Ranges below 6 bar take 1.5 x range without damage and burst at 3 x range. From 6 bar the figures are 3 x range and 5 x range.
My range is not in the list. Can it be supplied?
Any range from 0 to 0.2 bar up to 0 to 600 bar. Choose X, state the range in the request and it becomes a line on the quote.
Other pressure transmitters
See all 31-
PT10Millivolt pressure sensor, glass-fused cell
0 to 6 up to 0 to 600 bar · 10 to 15 mV/V, four-wire -
PT11Wide-range welded stainless transmitter
0 to 0.2 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT12Glass-fused pressure transmitter, 0.3 % grade
0 to 6 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT13Glass-fused transmitter, 0.5 % grade
0 to 6 up to 0 to 600 bar · Gauge, sealed gauge, absolute -
PT14Low-range millivolt pressure sensor
0 to 0.4 up to 0 to 70 bar · 10 mV/V, four-wire -
PT15Low-pressure transmitter, vacuum to 6 bar
-1 bar up to 6 bar · 4 to 20 mA or voltage -
PT16Precision transmitter, ±0.1 % of span
0 to 0.4 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT17Ceramic flat-diaphragm pressure transmitter
0 to 2 up to 0 to 25 bar · 4 to 20 mA, voltage or RS485