Clamp-mount flush diaphragm transmitter
Flush 316L diaphragm on a clamp flange for viscous, particle-laden, food and pharma media, up to 0 to 25 bar.
- Range
- 0 to 0.4 up to 0 to 25 bar
- Accuracy
- ±0.5 % of span
- Output
- 4 to 20 mA, two-wire
- Process connection
- Clamp flange, flush diaphragm
- Built to the order code you configure
- Datasheet and dimension drawing with the quote
- Other ranges and connections quoted on request
PT60 has its diaphragm flush with the face of a clamp flange, so there is no port or cavity where the medium can settle, set or block. The wetted parts and the housing are 316L stainless steel, and the sensing element is fully welded. Ranges run from 0 to 0.4 bar up to 0 to 25 bar, gauge or absolute.
It is made for food and beverage lines, pharmaceutical and biotech process equipment, and for viscous or particle-laden media such as paint, paper stock and polyurethane components. In water and pumping it fits sludge and slurry lines where a threaded port with a pressure channel would clog.
Output is 4 to 20 mA on two wires from 15 to 30 V DC, with ±0.5 % of span accuracy and a frequency response of 3.2 kHz. Connection is by DIN 43650 form A connector or cable outlet, and a local display is available. Without the display the transmitter runs at -20 to 85 °C, with it at -20 to 70 °C.
Typical points
- Pump discharge and suction pressure
- Hydraulic system pressure on machines
- Compressed air headers
- Chilled and heating water circuits
Measurement
| Pressure type | Gauge, absolute |
|---|---|
| Ranges | 0 to 0.4 bar up to 0 to 25 bar |
| Accuracy | ±0.5 % of span |
| Overpressure | 1.5 x range |
| Burst pressure | 3 x range |
| Long-term stability | ±0.2 % of span per year |
| Zero drift | ±0.02 % of span per °C |
| Span drift | ±0.02 % of span per °C |
| Compensated range | -10 to 85 °C |
| Frequency response | 3.2 kHz (-3 dB) |
Medium and environment
| Operating temperature | -20 to 85 °C; -20 to 70 °C with display |
|---|---|
| Medium above 70 °C | Cooling element recommended |
| Wetted parts | Stainless steel 316L, flush diaphragm |
| Housing | Stainless steel 316L |
Electrical
| Output | 4 to 20 mA, two-wire |
|---|---|
| Supply | 15 to 30 V DC |
| Maximum load | (Supply voltage minus 9 V) / 20 mA |
| Electrical connection | DIN 43650 form A connector or cable outlet |
| Protection | IP65 |
Display and switching
| Display | Local display, optional |
|---|
Mechanical
| Process connection | Clamp flange with flush diaphragm |
|---|---|
| Accessories | Clamp and gasket, optional |
| Sensing element | Fully welded |
Common configurations. Any combination from the ordering code can be quoted.
| Range | Pressure type | Electrical connection | Display | Order code |
|---|---|---|---|---|
| 0 to 0.4 bar | Gauge | DIN 43650 form A | None | PT60-K40-G-D-N |
| 0 to 1 bar | Gauge | DIN 43650 form A | Local display | PT60-001-G-D-LD |
| 0 to 4 bar | Gauge | Cable outlet | None | PT60-004-G-C-N |
| 0 to 6 bar | Absolute | DIN 43650 form A | None | PT60-006-A-D-N |
| 0 to 10 bar | Gauge | DIN 43650 form A | Local display | PT60-010-G-D-LD |
| 0 to 25 bar | Gauge | Cable outlet | None | PT60-025-G-C-N |
One code from each group, in this order. Example: PT60-K40-G-D-N.
Range
| K40 | 0 to 40 kPa (0.4 bar) |
|---|---|
| 001 | 0 to 1 bar |
| 002 | 0 to 2 bar |
| 004 | 0 to 4 bar |
| 006 | 0 to 6 bar |
| 010 | 0 to 10 bar |
| 016 | 0 to 16 bar |
| 025 | 0 to 25 bar |
| X | Other range, state in the request |
Pressure type
| G | Gauge |
|---|---|
| A | Absolute |
Electrical connection
| D | DIN 43650 form A connector |
|---|---|
| C | Cable outlet |
Display
| N | No display |
|---|---|
| LD | Local display |
- DatasheetPDF
- Dimension drawingSent with the quote
- Calibration certificate, per unit on requestSent with the quote
Questions about PT60
Something else? Ask us about this model
Which clamp size does it fit?
State the clamp size of the fitting on your line in the request. The quote confirms the flange, and the clamp and gasket can be added as separate lines.
Can it go on hot media?
The transmitter runs at -20 to 85 °C, or -20 to 70 °C with the display. Above 70 °C medium temperature a cooling element is recommended. State the medium temperature in the request and the quote covers it.
PT60 or PT61?
Both have a flush 316L diaphragm and 4 to 20 mA output. PT60 mounts on a clamp flange and goes up to 0 to 25 bar. PT61 screws into an M20 x 1.5 or G1/2 port and goes up to 0 to 70 bar.
Other pressure transmitters
See all 31-
PT10Millivolt pressure sensor, glass-fused cell
0 to 6 up to 0 to 600 bar · 10 to 15 mV/V, four-wire -
PT11Wide-range welded stainless transmitter
0 to 0.2 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT12Glass-fused pressure transmitter, 0.3 % grade
0 to 6 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT13Glass-fused transmitter, 0.5 % grade
0 to 6 up to 0 to 600 bar · Gauge, sealed gauge, absolute -
PT14Low-range millivolt pressure sensor
0 to 0.4 up to 0 to 70 bar · 10 mV/V, four-wire -
PT15Low-pressure transmitter, vacuum to 6 bar
-1 bar up to 6 bar · 4 to 20 mA or voltage -
PT16Precision transmitter, ±0.1 % of span
0 to 0.4 up to 0 to 600 bar · 4 to 20 mA or voltage -
PT17Ceramic flat-diaphragm pressure transmitter
0 to 2 up to 0 to 25 bar · 4 to 20 mA, voltage or RS485