Pressure data loggers

Compact wireless pressure sensor, tilt alarm

Model PR12

Self-contained NB-IoT or LoRaWAN sensor for cylinders and fire mains, up to 1000 bar, 3-year lithium cell.

Network
NB-IoT or LoRaWAN
Battery life
3 years, 12-hour heartbeat
Range
0 to 10 up to 0 to 1000 bar
Accuracy
±1 % of span

Configure PR12

Process connection
Network
Order code PR12-010-M20-NB

No payment now. The quote comes back with the price, the lead time and the documents.

  • Built to the order code you configure
  • Datasheet and dimension drawing with the quote
  • Other ranges and connections quoted on request

PR12 is a compact, self-contained wireless pressure sensor: a short cylindrical body on a male process connection, with a built-in 3.0 V lithium battery and no external wiring. It reports over NB-IoT on the 800, 900 and 1800 MHz bands, or over LoRaWAN, and sends a heartbeat every 12 hours. On that schedule the 1500 mAh battery lasts 3 years.

It is meant for points nobody visits often: gas suppression cylinders and fire extinguishers, sprinkler and hydrant mains, heating circuits and water pipelines in buildings. A tilt sensor raises an alarm when the unit is knocked 10° or more out of position, and alarms also go out on pressure loss and when the battery falls below 2.8 V.

Ranges run from 0 to 10 bar up to 0 to 1000 bar, with 0 to 300 bar as the default. Accuracy is ±1 % of span. Process connections are M20 x 1.5, G1/4 or M10 x 1, the housing is IP65, and it works from -20 to 80 °C at up to 95 % relative humidity without condensation.

Typical points

  • Distribution network and pressure zone surveys
  • Pressure transients after pump trips
  • Hydrant and valve chamber monitoring
  • Temporary logging during commissioning

Questions about PR12

Something else? Ask us about this model

What happens when a cylinder starts to leak?

The sensor pushes an alarm when the pressure drops, without waiting for the next 12-hour heartbeat. A knock that tilts it 10° or more raises its own alarm.

How long does the battery last?

Three years with one heartbeat every 12 hours. A low battery alarm goes out when the cell falls below 2.8 V.

Which range should I order?

The default is 0 to 300 bar. Ranges run from 0 to 10 bar up to 0 to 1000 bar. State the range in the request and it becomes a line on the quote.